11 Mechanical installation
11.6

Installation of coordination unit on Fire Door installations

Before installing the transmission unit do step a-e below. Screw in the two steering pins (1) for the
coordinator base.
1
Mount the rotor (parts 2 to 4 below) before the motor is installed on the back plate. Install the
control unit when the installation of the coordination unit is completed.
If the coordination unit will be installed on an existing installation it is possible to move the control
unit a little bit to be able to reach the motor unit during installation.
Link rod length = hinge to hinge - 980 mm
a Loosen the screws (2) and remove the clutch cap (3) from the rotor (4).
b Turn the clutch cap (3) depending on PULL or PUSH installation. PULL visible for PULL-installation
and PUSH visible for PUSH-installation.
c Fasten the screws (2).
52
4
3
Issue 2021-06-07
1
Steering pin
2
Screw
3
Clutch cap
2
4
Rotor
1020527-DIen-3.0