Control Units; Cus7 (Dab305Cu); Arm System Selection - DITEC DAB305 Installation And Service Manual

Swing door operator
Hide thumbs Also See for DAB305:
Table of Contents

Advertisement

12.1

Control units

12.1.1

CUS7 (DAB305CU)

Encoder
Motor
PUSH
Motor
PULL
Lock Kick
Double acting
OK
Green
DIP-switch
DIP-switch
Push & Go
1
PAG
=
Safety mat
2
MAT
=
Stop on stall
3
SOS
=
Activation delay
4
AD
=
Inverse installation
5
INV
=
Arm system setting
6
AS1
=
7
AS2
Arm system setting
=
Note! Connect the motor cable to either PUSH or PULL depending on arm system.
12.1.2

Arm system selection

Factory set arm configuration is PUSH, if other is required:
Select arm configuration on the DIP-switches according to the table below.
Type of arm system
PUSH
PULL
DAB805PLA5 (narrow
door)
Sliding PUSH
Note! After changing any system selection a new LEARN must be carried out.
1020527-DIen-3.0
Synchronizing of double doors
Key hold open time
DIP-switch
ON
5 s
1
1.5 s
30 s
HOT / KHOT
7 s
12 s
4 s
5 s
CLSP
12 s
OPSP
ALARM
Red
External LED indicator = LED
ON=1
OFF=0
AS 1
DIP 6
0
1
0
1
Issue 2021-06-07
Hold open time
Closing torque
Symmetric cam (jumper off)
Asymmetric cam (jumper on)
Program selector
2 3 4 5 6 7
2,5 s
= Learn button
LRN
Power assist
LED
Closing speed
Opening speed
AS 2
DIP 7
0
0
1
DAB805PLA5
1
12 Electrical connection
+24V DC
LOUT
= Lock-out for OPD ( –)
= Overhead presence detection/mat safety
OPD
= Inner impulse
IIMP
= Ground
GND
OPD
= Overhead presence detection (incl. 24 V,
LOUT and Safety Impulse)
PUSH
PUSH
PULL
PULL
PULL
Sliding
Sliding
PUSH
PUSH
59