Swing Door Operator
Ditec DAB305
Installation and Service Manual
Original instructions
1020527-DIen-3.0 Issue 2021-06-07

Advertisement

Table of Contents
loading

Summary of Contents for DITEC DAB305

  • Page 1 Swing Door Operator Ditec DAB305 Installation and Service Manual Original instructions 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 2 © All rights in and to this material are the sole property of ASSA ABLOY Entrance Systems AB. Copying, scanning, alterations or modifications are expressly forbidden without the prior written consent of ASSA ABLOY Entrance Systems AB. Rights reserved for changes without prior notice.
  • Page 3: Table Of Contents

    Intended use ....................................Safety precautions ..................................Electronic equipment reception interference ........................Environmental requirements ..............................Technical specifications ................................ Permitted door weight and door width for Ditec DAB305 ....................How the Ditec DAB305 works ............................Opening ......................................Closing ....................................... Control switch ....................................
  • Page 4 Battery backup unit ..................................Cover piece kit ....................................Closing time board kit ................................. Fire kit ....................................... Labels ......................................... Pre-installation ..................................10.1 General tips/Safety concerns ..............................10.2 Operator/Door handing ................................10.3 Installation examples ..................................10.4 Fastening requirements (but not included) ......................... 10.5 Tools required ....................................
  • Page 5 Troubleshooting ..................................18.1 Error indication ....................................Service/Maintenance ................................1020527-DIen-3.0 Issue 2021-06-07...
  • Page 6 Issue 2021-06-07 1020527-DIen-3.0...
  • Page 7: Revision

    1 Revision Revision Following pages have been revised: Page Revision 2.0 → 3.0 Updated Entrematic Group to Ditec. Updated the image. Updated the image. 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 8: Instructions For Safe Operation

    2 Instructions for safe operation Instructions for safe operation • Failure to observe the information in this manual may result in personal injury or damage to equipment. • To reduce the risk of injury to persons - use this operator with single or double pedestrian swinging or folding doors only.
  • Page 9: Important Information

    Important information Intended use The Ditec DAB305 is an automatic swing door operator developed to facilitate entrances to buildings and within buildings through swing doors. The Ditec DAB305 is an electromechanical operator approved for fire door applications. It is to be installed indoors where it is suitable for al- most all types of external and internal swing doors.
  • Page 10: Environmental Requirements

    3 Important information Environmental requirements Ditec products are equipped with electronics and may also be equipped with batteries containing materials which are hazardous to the environment. Disconnect power before removing electronics and battery and make sure it is disposed of properly according to local regulations (how and where) as was done with the packaging material.
  • Page 11: Technical Specifications

    ASSA ABLOY Entrance Systems AB Address: Lodjursgatan 10, SE-261 44 Landskrona, Sweden Type: Ditec DAB305 Mains supply: 100-240 V AC +10/-15%, 50/60 Hz, mains fuse max 10A (building installation) Note! The mains supply shall be installed with protection and an...
  • Page 12: Permitted Door Weight And Door Width For Ditec Dab305

    4 Technical specifications This product is to be installed internally. Permitted door weight and door width for Ditec DAB305 J=140 kgm² PUSH arm PUSH arm PUSH arm PULL arm PULL arm J=80 kgm² PULL arm Door width (m) Issue 2021-06-07...
  • Page 13: How The Ditec Dab305 Works

    How the Ditec DAB305 works The swing door operator Ditec DAB305 uses a DC motor which is connected to the output shaft by a combination of a worm gear and spur gears. The push- or pull arm system that is connected to the output shaft opens the door in a surface mounted application.
  • Page 14: Opening

    5 How the Ditec DAB305 works Opening When an activation signal is received by the control unit, the door is opened at the installer-adjusted opening speed. Before the door is fully open at back check, it slows automatically to low speed.
  • Page 15: Extended Closing Torque (Cltq)

    5 How the Ditec DAB305 works 5.4.3 Extended closing torque (CLTQ) If the potentiometer CLTQ is set to 0°, the door will close with normal spring power. If the poten- tiometer is turned clockwise, the motor will increase the closing torque. Extended closing torque will be reduced to zero: •...
  • Page 16: Double Acting

    5 How the Ditec DAB305 works 5.4.10 Double acting Opening inwards and with panic break out outwards Functions on the extension unit DAB905ESE Also see page 61 for more information. 5.5.1 KILL or FIRE function In the event that the KILL or FIRE circuit is activated, all Safety Functions of the door will be overridden causing the door to close even though an object or person may be in the door's path of travel, and therefore may be subject to injury.
  • Page 17: Open/Close Impulse

    5 How the Ditec DAB305 works 5.5.5 OPEN/CLOSE impulse The impulse will open the door and the door will stay open until a new impulse is given. If no impulse is given the door will close after 15 minutes. This can be made infinite by changing group of para- meters, see page 77.
  • Page 18: Nurse And Bed Functionality

    5 How the Ditec DAB305 works 5.5.7 Nurse and bed functionality Solution 1 Connect a bridge between 3 and 7 on the secondary DAB905ESE. Use any impulse on primary to open primary door. Use Open/Close impulse on secondary to open both doors.
  • Page 19: Presence Detection Swingpath, Door Mounted

    5 How the Ditec DAB305 works 5.6.2 Presence detection swingpath, door mounted When a sensor that is mounted on the swing side of a door detects an object, it will send a command to the control unit to stall the door. If the control unit has received a short signal from the sensor and there is still hold open time left on the control unit, the door will continue on its way open if the object has cleared.
  • Page 20: Models

    6 Models Models The Ditec DAB305 is available as single doors model: The operator is non-handed and not dependent on the hinges. The operator suits both pushing and pulling arm systems. Single operator, surface mounted The product is delivered complete with back plate, control unit, end plates and cover. Total cover length CL includes end plates.
  • Page 21: Double Operator, Surface Mounted

    Two operators can be mounted under the same cover (full length or a modular) to open one door each. Pushing and pulling arm system shown (double egress). It is also possible to use two pushing or two pulling arm systems. Full length cover. Not available from Ditec, to be arranged locally. = 1684 min. = 3284 max.
  • Page 22: Part Identification

    7 Part identification Part identification Issue 2021-06-07 1020527-DIen-3.0...
  • Page 23 7 Part identification Item No. Art. No. Description DAB905ESE Kit for Security & Impulse DAB905ESA Kit for Safety DAB905SYN Sync cable double doors (L=3000 mm) 6DAB205EC Encoder cable 6DAB305TUF Transmission unit kit PUSH/PULL 6DAB305MSW Micro switch kit 6DAB305SAK Stop arm kit 6DAB305CU Control unit without DAB905ESA/ESE boards DAB905CO...
  • Page 24: Arm Systems

    8 Arm systems Arm systems The installation process of arm systems is the same for Fire door installations and Inverse installations. Pushing installation with PUSH-arm This arm system is delivered with drive arm, telescopic part and door fitting. It is used if the oper- ator is installed on the wall on the opposite side of the door swing, and approved for fire door ap- plication for A up to 300 mm.
  • Page 25: Pulling Installation With Pull-Arm

    8 Arm systems Pulling installation with PULL-arm This arm system is delivered with drive arm, guide shoe and door fitting. Approved for fire door application for A up to 130 mm. DAB805PLA3 (A = -20-130 mm) DAB805PLA5 (A = -20-65 mm), only for LE Performance 150 mm 20 mm extension Extension 20 mm for PULL/PAS and lower mounting of slide track profile.
  • Page 26: Pushing Installation With Pull-Arm

    8 Arm systems Pushing installation with PULL-arm This arm system consists of main arm, slide track, guide shoe and shaft adapter. It can be fitted on combinations of doors and jambs (walls), where the wall thickness does not exceed approx. 114 mm.
  • Page 27: Drive Shaft Extension Kits

    8 Arm systems Drive shaft extension kits 70 mm 70 mm 50 mm 50 mm 20 mm 20 mm Art. No.: DAB805SE22 Art. No.: DAB805SE52 Art. No.: DAB805SE72 Art. no: xxxxx Art. no: xxxxx Art. no: xxxxx Lower adapter M10, used for 20 mm lower installation height. Art.
  • Page 28: Options

    9 Options Options Control switches 9.1.1 4-position switch COM400MHB/MKB (operates the electric lock) Position Function The door is closed. The door cannot be opened with inner and outer activation units. The door is locked if an electromechanical locking device has been fitted. The door can be opened with a key switch (if fitted).
  • Page 29: Led Cable

    9 Options LED Cable External status indicator LED Art. No.: DAB905LED Battery backup unit Note! Disconnect mains when replacing battery. Risk of battery explosion if wrong type of bat- tery is used. Art. No.: DAB905BAT3 Cover piece kit Art. No.: DAB805CMP1 Closing time board kit To fulfill the DIN 18263-4 standard it is necessary to mount and connect this board to the lock kick.
  • Page 30: Fire Kit

    9 Options Fire kit For fire door installations. Containing a smoke detector ORS142W with silver cover, a Reset & Indication Device, Closing brake kit and a three pole connection cable harness. Art. No.: DAB905FIK Labels Label kit- including all below Emergency break-out, DIN right door Emergency break-out, DIN left door Click!
  • Page 31: Pre-Installation

    10 Pre-installation Pre-installation 10.1 General tips/Safety concerns In all instances, where work is being done, the area is to be secured from ped- estrian traffic, and the main power removed to prevent injury. • Make sure that the power is off before installing. •...
  • Page 32: Installation Examples

    Expansion-shell bolt, min. M6x85, UPAT PSEA B10/25, min. 50 mm from the underside * Ditec minimum recommended requirements. Building Codes may give different specifications. ** Thinner wall profiles (3-5 mm) must be reinforced with rivet nuts. *** Thinner wall profiles (4-6 mm) must be reinforced with rivet nuts.
  • Page 33: Tools Required

    10 Pre-installation 10.5 Tools required • Metric Allen keys 1.5; 2.5; 3; 4; 5 and 6 mm • Torque wrench 8 Nm, 14 Nm and 50 Nm • Allen key 1.5; 2.5 and 3 mmwith spherical tip • Torx T10 and T20 •...
  • Page 34: Mechanical Installation

    11 Mechanical installation Mechanical installation The operator is mounted on either side of the door header depending on type of doors. The door is controlled with a push or pull arm system. If a coordination unit is to be installed on a double door installation, mount the coordinator base with rotor before mounting the transmission unit, see page 52.
  • Page 35 11 Mechanical installation A = 192 B = 557 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 36 11 Mechanical installation A = 192 B = 557 150 mm 42 mm Issue 2021-06-07 1020527-DIen-3.0...
  • Page 37: Push Arm System

    11 Mechanical installation 11.1 PUSH arm system PUSH 51 mm 2 - 25 mm 25 - 45 mm 71 mm 20 mm 45 - 75 mm 101 mm 50 mm 75 - 95 mm 121 mm 70 mm 0 - 367 Reveal 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 38 11 Mechanical installation Operator with PUSH arm system DIN Right DIN Right (mm) (mm) Cable inlet Note! Screw head must be flush with back plate surface. 8 Nm C L 2 C L 1 Issue 2021-06-07 1020527-DIen-3.0...
  • Page 39 11 Mechanical installation Continuous "Operator with PUSH arm system" DIN Left DIN Left (mm) (mm) Cable inlet Note! Screw head must be flush with back plate surface. C L 1 C L 2 8 Nm C L 1 C L 2 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 40 11 Mechanical installation Continuous "Operator with PUSH arm system" DIN Left DIN Right DIN Left DIN Right 20° 1. Pre-tension the spring 2. Secure the pre-tension by the pin Let the stop arm locator and the stop arm be loose. Do not tighten.
  • Page 41 11 Mechanical installation Continuous "Operator with PUSH arm system" MARK Align the marks between arm and adaptor. Align the arm with the operator mark. 15 Nm 15 Nm 90° Loosen the four screws. (2x) Fasten the arm system to the door. 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 42 11 Mechanical installation 10 lbf·ft (14 Nm) 14 Nm Tighten the four screws. The door must be closed. Hold the door a bit open and re- move the start position pin. 50 Nm 50 Nm See the table on page for available extensions.
  • Page 43: Pull Arm System

    11 Mechanical installation 11.2 PULL arm system Slim slide track PULL 48 mm 20 mm 68 mm 50 mm 98 mm 70 mm 118 mm A = -20-130 Note! Measurement Z must be reduced by 20 mm if lower adapter from kit DAB805LA is used. 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 44 11 Mechanical installation Operator with PULL arm system DIN Left DIN Left (mm) (mm) Cable inlet Note! Screw head must be flush with back plate surface. 8 Nm C L 2 C L 1 Issue 2021-06-07 1020527-DIen-3.0...
  • Page 45 11 Mechanical installation Continuous "Operator with PULL arm system" DIN Right DIN Right (mm) (mm) Cable inlet Note! Screw head must be flush with back plate surface. 6 5 2 C L1 C L 2 8 Nm C L 1 C L 2 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 46 11 Mechanical installation Continuous "Operator with PULL arm system" DIN Right DIN Left DIN Right DIN Left 20° Let the stop arm locator and the stop arm be loose. Do not tighten. Issue 2021-06-07 1020527-DIen-3.0...
  • Page 47 11 Mechanical installation Slim slide track Attach the slide track (1) to the door with the guide shoe (2) fitted into the track. Use appropriate screws. Click Click Slide track Guide shoe 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 48 11 Mechanical installation Continuous. "Operator with PULL arm system" It is important to align the marks correctly. If necessary move one mark at a time. This corresponds to approx. 3° and will give a precision of ±1,5°. Align the marks. 50 Nm 50 Nm Hold the door a bit open and remove...
  • Page 49: Operator With Sliding Push Arm System

    11 Mechanical installation 11.3 Operator with sliding PUSH arm system Slim slide track PUSH 48 mm 2-25 mm 20 mm 68 mm 25-45 mm 50 mm 98 mm 45-75 mm 70 mm 75-95 mm 118 mm Max. 114 mm Max. 114 Reveal See instructions for PULL installation.
  • Page 50: Inverse Installation With Push Arm System

    11 Mechanical installation 11.4 Inverse installation with PUSH arm system Remove the microswitch lever (1), but not the micro switch (2). Remove also the stop arm (3). Microswitch lever Micro switch Stop arm Note! Set dip switch INV to ON for Inverse operation, see 12.1.1 on page 59.
  • Page 51: Inverse Installation With Pull Arm System

    11 Mechanical installation 11.5 Inverse installation with PULL arm system Remove the microswitch lever (1), but not the micro switch (2). Remove also the stop arm (3). Microswitch lever Micro switch Stop arm Note! Set dip switch INV to ON for Inverse operation, see 12.1.1 on page Spring pre-tension should not be more than 7 mm (measured between the washer and the adjust- ment nut).
  • Page 52: Installation Of Coordination Unit On Fire Door Installations

    11 Mechanical installation 11.6 Installation of coordination unit on Fire Door installations Before installing the transmission unit do step a-e below. Screw in the two steering pins (1) for the coordinator base. Steering pin Mount the rotor (parts 2 to 4 below) before the motor is installed on the back plate. Install the control unit when the installation of the coordination unit is completed.
  • Page 53 11 Mechanical installation d Mount the rotor (4) on the motor unit (7) with the screw (5) and washer (6) on the primary drive unit = for the door that opens first and closes last. Rotor Screw Washer Motor unit e Release the brake (26) by pushing in the linkage arm (14), so that the brake (26) is opened, push the fork (27) into the the coordinator base (15).
  • Page 54 11 Mechanical installation Mount the coordinator base (15) with the two screws (8) on the primary drive unit. Remove the screw (9) and throw the washer (24) away when mount the acceptor (11) on the adjuster (10). Mount the screw (9) through the acceptor (11). g Mount the transmission unit.
  • Page 55 11 Mechanical installation Mount the link rod (12) with its adaptor (13) into the linkage arm (14). Link rod Adaptor Linkage arm Mount on the other side of the link rod (12) to the secondary motor unit with the signal (16). Fasten the stop screw (17).
  • Page 56 11 Mechanical installation k Adjust the release of the brake by loosening the joint (18) and turning the link rod (12) close to the primary drive unit. Make the angle between the doors near closed position. Link rod Joint Route the cables, see illustrations on page 35. m Put the grease on the rod support.
  • Page 57 11 Mechanical installation n Mount the follower roller (20) at the leading edge close to the top of the secondary door leaf (21) with the appropriate screws (23). Follower roller Secondary door leaf Primary door leaf Screw 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 58: Electrical Connection

    12 Electrical connection Electrical connection Note! During any work with the electrical connections the mains must be disconnected. • Place the electric switch easily accessible from the operator. If an plug contact is used in the installation the wall socket shall be placed easily accessible from the operator. •...
  • Page 59: Control Units

    12 Electrical connection 12.1 Control units 12.1.1 CUS7 (DAB305CU) Synchronizing of double doors Key hold open time Hold open time DIP-switch Closing torque Encoder Symmetric cam (jumper off) Asymmetric cam (jumper on) Motor Program selector PUSH 2 3 4 5 6 7 Motor +24V DC PULL...
  • Page 60: Extension Units Dab905Ese / Dab905Esa

    12 Electrical connection 12.1.3 Extension units DAB905ESE / DAB905ESA Installation Torx T10 DAB905ESA 5 mm nut driver Electrical power contact DAB905ESE Tag strip long 2 pcs DAB905ESA / DAB905ESE short 1 pc DAB905ESA / DAB905ESE CUS7 (DAB305CU) Issue 2021-06-07 1020527-DIen-3.0...
  • Page 61: Extension Unit Dab905Ese

    12 Electrical connection 12.1.4 Extension unit DAB905ESE This extension unit has inputs for electro-mechanical lock, program selector, batteries, KILL function, OPEN/CLOSE, KEY opening and outer impulse. Functions Battery backup unit +24 V DC (+) 24 VDC OPEN Program selector EXIT Unlocked signal from lock KRST KILL reset (see jumper below)
  • Page 62: Extension Unit Dab905Esa

    12 Electrical connection 12.1.5 Extension unit DAB905ESA This extension unit has inputs for door mounted sensors, which can give presence impulse on approach side and/or presence detection on swing path side. Relay output for error indication or door indication is also integ- rated.
  • Page 63: Installation On Double Doors

    12 Electrical connection 12.1.6 Installation on double doors If the operators are to be mounted at the same height with pushing and pulling arm systems, the height is determined by the pulling arm system, PULL. The pushing arm system PUSH must always have a shaft extension, minimum 50 mm, maximum 70 mm to match the mounting heights visually.
  • Page 64: Double Door Installations

    12 Electrical connection 12.3 Double door installations There are three different types of double door installations: • Rebated Has an overlapping primary door, can be opened synchronously if it is not jamming and must be closed asynchronously to avoid that the doors will jam or close in the wrong order. •...
  • Page 65: Sensor Cable Inlet

    12 Electrical connection 12.5 Sensor cable inlet Art. No.: DAB805SCI Alt. 1 Alt. 1 ø 3.7 Alt. 2 Alt. 2 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 66: Reset And Indication Device For Fire Doors

    12 Electrical connection 12.6 Reset and indication device for Fire Doors Art. No.: DB905RSD CL=840 CL= Optional CL=840 CL=Optional Reset & Indication device Reset & Indication device Smoke detector B Smoke detector ø 3.7 Issue 2021-06-07 1020527-DIen-3.0...
  • Page 67 12 Electrical connection CU-300 Master CUS7 (DAB305CU) Master 2 3 4 5 6 7 OK (Green) ALARM (red) DAB905ESE Master EXU-SI Master NC Kill switch Fire alarm reset NC Kill switch (Parameter group 13) Fire alarm reset 0.5 s Additional smoke Kill switch and close Kill switch and detector is connected...
  • Page 68: Start-Up

    13 Start-up Start-up 13.1 Spring pre-tension The spring pre-tension is factory set to EN4. The closing torque (spring force) is adjusted by an hexagon nut placed at the end of the spring. Turning the nut clockwise increases the force. One turn equals a torque change of approx.
  • Page 69: Micro Switch

    13 Start-up 13.2 Micro switch Check and adjust the micro switch, controlling the lock kick at power failure. 13.3 Adjusting the door stop a Close the door. b Open the door to required open position, plus approx. 15 mm. Put a doorbuffer under the door. ≈...
  • Page 70 13 Start-up d When stop arm is on the bottom of the operator, loose the stop arm locator and the stop arm. Mount the stop arm on the splines, as close as possible to the stop block 3). Mount the stop arm locator.
  • Page 71: Auto-Learn-Automatically Sets Back And Latch Check (Recommended)

    13 Start-up 13.4 Auto-learn-automatically sets back and latch check (recommended) This learning is performed by pushing the LEARN BUTTON (LRN). • Switch on the electrical power (the operator will find its closed position) and make sure the LED is on. •...
  • Page 72: Push The Learn Button (Lrn)

    13 Start-up 13.4.1 Push the LEARN BUTTON (LRN) The door has no safety during auto-learn cycle. Remain clear of swing path of door, as door may close rapidly. Note! If the learn button is just pushed ones, a learn for reveal 0-100 mm will be carried out. For greater reveal keep the button pressed, and release it when the status LED is blinking for desired reveal, see below table.
  • Page 73: Connection Of Activation Units And Accessories

    When sensors are used in order to avoid contact with the door leaf it is required that the presence detect sensor and the presence impulse sensor fulfills Performance Level = c according to EN ISO 13849-1. These sensors shall also be monitored (tested) by Ditec DAB305 door operator. *** Note! When using the quick connector, opening and ***) Note! When using the quick connector, closing side will be reversed.
  • Page 74: Cover

    Secure cover with the screw. When properly installed and adjusted, attach the product label, which includes the CE mark on the right side of the lower part of the operator cover (see illustration). Apply the Ditec logotype to the cover see illustration. XXXXXXX XXXXXXXXXXXXX XXXXXXXXXX ART.
  • Page 75: Signage

    15 Signage Signage XXXXXXX XXXXXXXXXXXXX XXXXXXXXXX ART. NO. DESIGNATION TYPE XXXXXX XXXX XXXXXXXXXXX PROJECT/SERIAL NO. YEAR+MONTH TEMPERATURE XXXXXXX XXXX XX/XX XXXXX LOAD XXXXXXX PROD. VERSION CLASSIFICATION DIN 18650-1:2010 CERTIFIERING SÜD KONTROLL 1002 xxxxxxx xxxxxxx No entry Click! No entry Click! Automatic door 40 mm...
  • Page 76: Advanced Settings

    16 Advanced settings Advanced settings 16.1 Learn with advanced setting of “back- and latch-check” See the prerequisites for performing a “learn” in section Auto-learn-automatically sets back and latch check (recommended) on page 71. a Push the button once as for auto-setting. The status LED starts to blink.
  • Page 77: Changing Group Of Parameters (Level 2)

    16 Advanced settings 16.3 Changing group of parameters (Level 2) a Disconnect batteries if any. b Disconnect the mains. c Press the LEARN BUTTON (LRN) and keep it depressed. d Connect the mains. e Watch the ERROR LED. Release the LEARN BUTTON after 2 flashes (LED is out). The ERROR LED flashes a number of short flashes that corresponds to the parameter group number (see table).
  • Page 78 16 Advanced settings Issue 2021-06-07 1020527-DIen-3.0...
  • Page 79 16 Advanced settings 1020527-DIen-3.0 Issue 2021-06-07...
  • Page 80: Classification (Level 3)

    16 Advanced settings 16.4 Classification (Level 3) a Disconnect batteries if any. b Disconnect the mains. c Press the LEARN BUTTON (LRN) and keep it depressed. d Connect the mains. e Watch the ERROR LED. Release the LEARN BUTTON after 3 flashes (LED is out). g Identify the current classification The ERROR LED flashes an amount of short flashes that correspond to the classification number.
  • Page 81: Overhead Presence Detection And Interlock (Level 4)

    16 Advanced settings 16.5 Overhead Presence Detection and Interlock (Level 4) a Disconnect batteries if any. b Disconnect the mains. c Press the LEARN BUTTON (LRN) and keep it depressed. d Connect the mains. e Watch the ERROR LED. Release the LEARN BUTTON after 4 flashes (LED is out). g Identify the current monitoring The ERROR LED flashes an amount of short flashes that correspond to the status number.
  • Page 82: Enhanced Lock Kick, Fire Input And Extended Arm Selection (Level 5)

    16 Advanced settings 16.6 Enhanced Lock Kick, Fire Input and Extended Arm Selection (Level 5) a Disconnect batteries if any. b Disconnect the mains. c Press the LEARN BUTTON (LRN) and keep it depressed. d Connect the mains. e Watch the ERROR LED. Release the LEARN BUTTON after 5 flashes (LED is out).
  • Page 83: Guide For Installation And Adjustments

    17 Guide for installation and adjustments Guide for installation and adjustments 17.1 Complementary Safety Devices Swing Doors If there is any risk for finger jam, add finger protection strip at the hinge side for internal doors, article No. DAB805FPI or DAB805FP19/20. 17.2 Swing Doors Opening and Closing Time Adjust, as a minimum, the operator's opening and closing time according to the diagram below.
  • Page 84: Diagrams For Door Weight

    17 Guide for installation and adjustments 17.3 Diagrams for Door weight a Measure the door width (DW) and the door height (DH) in metres for one door leaf only. b Calculate the area DW x DH. c Select diagram for your type of door and the actual glass thickness. Find the weight. Example: Aluminium door with measurement DW = 1.5 m, DH = 2 m and glass thickness 12 mm.
  • Page 85 18 Troubleshooting Troubleshooting Fault Possible reasons why Remedies/Explanations The door does not open Control switch is set to OFF Change the setting of the control switch The motor does not start Mains power is missing Check the mains power and fuse in the building Activation unit does not function Strap impulse inputs Presence detection is activated...
  • Page 86 18 Troubleshooting 18.1 Error indication • During normal operation the status LED on the control unit is illuminated. • An extinguished LED indicates that there is no electrical power. • A flashing light on the LED indicates that the operator is out of function (see table below). LED flash frequency/Display Reason Remedy...
  • Page 87 Service/Maintenance Regular inspections shall be made according to national regulations and product documentation by a Ditec-trained and qualified technician. The number of service occasions should be in accordance with national requirements and product documentation. This is especially important when the installation concerns a fire-approved door or a door with an emergency opening function.
  • Page 88 ASSA ABLOY Entrance Systems AB, Lodjursgatan 10, SE-261 44 Landskrona, Sweden www.ditecautomations.com...