Technical data
13.7

Installation height

13.8

Motor data

Electrical data
Identity code
Phases, protec‐
specification
tion
S
3-phase, IP 55
R
3-phase, IP 55
V0
1-phase, IP 55
L1
3-phase, II2GEx‐
eIIT3
L2
3-phase, II2GEx‐
deIICT4
P1
3-phase, II2GEx‐
eIIT3
P2
3-phase, II2GEx‐
dIICT4
V2
3-phase, II2GEx‐
deIICT4
78
Data
Maximum installation height*:
* with standard pumps: Fit at higher installation heights at your own
risk.
with ATEX pumps: We urgently advise that you contact a specialist
for ATEX motors at higher installation heights!
Rated voltage
Mains fre‐
quency
220-240 V /
50 Hz
380-420 V
250-280 V /
60 Hz
440-480 V
230 V / 400 V
50/60 Hz
230 V ±
50/60 Hz
220-240 V /
50 Hz
380-420 V
220-240 V /
50 Hz
380-420 V
250-280 V /
60 Hz
440-480 V
250-280 V /
60 Hz
440-480 V
400 V ±10%
50/60 Hz
Value Unit
1000 m above
Rated output
Remarks
0.75 kW
0.75 kW
1.5 kW
with PTC, speed
adjustment range
1:20 with external
fan 1-phase 230
V; 50/60Hz
1.1 kW
Variable speed
motor with inte‐
grated frequency
converter
0.75 kW
0.75 kW
with PTC, speed
control range 1:5
1.0 kW
0.75 kW
with PTC, speed
control range 1:5
1.5 kW
EX-variable speed
motor with inte‐
grated frequency
converter
standard
zero