Assembly - ProMinent Makro TZ Operating Instructions Manual

Diaphragm metering pump
Table of Contents

Advertisement

6

Assembly

Install the motor - with designs without
motor
Base
h
Fig. 7
1.
Select a suitable motor - it must correspond to the data for
one of the motors from the "Motor data" table - see Chapter
"Technical data".
2.
Fit the motor correctly on the flange (qualified personnel).
Observe the coupling operating instructions!
With a claw coupling: The claw on the motor shaft must be
fixed at the correct height, see corresponding figure and
table.
3.
As you have converted an "incomplete machine" into a com‐
plete machine, you must perform a conformity assessment,
risk assessment, issue an EC Declaration of Conformity, fit
your own company nameplate, ... .
4.
With ATEX pumps: additionally perform an ignition hazard
assessment.
5.
Complete the pump documentation / operating instructions.
WARNING!
The pump can break through the base or slide off it
Capacity too low
P_MOZ_0016_SW
Vibrations can disturb the liquid end valves.
Refer to the correct dimensional drawings on
our website www.prominent.com for assis‐
tance.
Compare the dimensions on the dimensional
drawing with those of the pump.
WARNING!
EX is relevant in areas at risk from explosion!
WARNING!
EX is relevant in areas at risk from explosion!
Ensure that the base is horizontal, flat and per‐
manently load-bearing.
Do not allow the base to vibrate.