Technical data
13.5.2
Air humidity
13.6
Housing degree of protection
13.7
Installation height
13.8
Motor data
Electrical data
Identity code
Phases, protection
specification
S
3-phase, IP 55
R
3-phase, IP 55
V0
1-phase, IP 55
L1
3-phase, II2GEx‐
eIIT3
L2
3-phase, II2GEx‐
deIICT4
P1
3-phase, II2GEx‐
eIIT3
68
Data
Maximum air humidity*:
*non-condensing (according to DIN IEC 60068-2-30)
Data
Protection against contact and humidity*
*according to DIN VDE 470 (EN IEC 60529)
Data
Maximum installation height*:
* with standard pumps: Fit at higher installation heights at your own risk.
with ATEX pumps: We urgently advise that you contact a specialist for
ATEX motors at higher installation heights!
Rated voltage
Mains frequency
220-240 V /
50 Hz
380-420 V
250-280 V /
60 Hz
440-480 V
230 V / 400 V
50/60 Hz
400 V ±
50/60 Hz
220-240 V /
50 Hz
380-420 V
220-240 V /
50 Hz
380-420 V
250-280 V /
60 Hz
440-480 V
Value Unit
95 % relative
Value Unit
1000 m above
Rated output
Remarks
1.5 kW
1.5 kW
2.2 kW
with PTC, speed
adjustment range
1:20 with external
fan 1-phase 230 V;
50/60Hz
2.2 kW
Variable speed
motor with inte‐
grated frequency
converter
1.5 kW
1.5 kW
with PTC, speed
control range 1:5
2.0 kW
humidity
Value
IP 55
standard
zero