13.6.2

Air humidity

13.6.3

Installation height

13.7

Housing degree of protection

13.8

Motor data

Electrical data
Tab. 8: HP2
Identity code
Phases, protection
specification
S
3-phase, IP 55
L1
3-phase, II 2G Ex eb
IIC T3 Gb
L2
3-phase, II 2G Ex de
IIC T4
P1
3-phase, II 2G Ex eb
IIC T3 Gb
P2
3-phase, II 2G Ex de
IIC T4
R/Z
3-phase, IP 55
Data
Maximum air humidity*:
*non-condensing (according to DIN IEC 60068-2-30)
Data
Maximum installation height*:
* with standard pumps: Fit at higher installation heights at your own risk.
with ATEX pumps: We urgently advise that you contact a specialist for
ATEX motors at higher installation heights!
Data
Protection against contact and moisture*
*according to EN IEC 60529
Rated voltage
Mains frequency
220-240 V /
50 Hz
380-420 V
250-280 V /
60 Hz
440-480 V
220-240 V /
50 Hz
380-420 V
220-240 V /
50 Hz
380-420 V
250-280 V /
60 Hz
440-480 V
250-280 V /
60 Hz
440-480 V
230 V / 400 V
50/60 Hz
Technical data
Value Unit
92 % relative
Value Unit
1000 m above
Rated output
Remarks
HP2a
0.37 kW
0.37 kW
0.37 kW
0.37 kW
with PTC, speed
control range 1:5
0.37 kW
0.37 kW
with PTC, speed
control range 1:5
0.37 kW
with PTC, speed
control range 1:20
with external fan 1-
phase 230 V; 50/60
Hz
humidity
standard
zero
Value
IP 55
83