Fig. 5-140 T2MI Replacer Card General Parameter Setting
Step 1: click the "Cards" option on the Web network management page.
Step 2: click the "Card n-T2MI Replacer Card";
Step 3: click "General";
Step 4: set the "Alarm" switch, the code rate switch of "Replacement Output Total
Bitrate", the T2MI Packet Searching Overtime Time and Replaced Output Total Bitrate
Value;
Step 5: click the "Apply" to put the setting into effect;
=======================================
Once the code rate of replacement output system and the code rate switch of
replacement output system are used together, the code rate setting can be valid
when the switch is turned on. In general, the switch is turned off. When the code
rate of the input source has a high fluctuation, the switch can be turned on and a
code rate is set for the replacement output system (such code rate shall be
greater than the valid code rate) to stabilize the code rate of the replacement
output system.
=======================================