5.
Release the parking brake.
6.
Tow the sprayer at less than 4.8 kph (3 mph).
7.
When finished, close the tow valve and torque it
to 7 to 11 N∙m (5 to 8 ft-lb).
Important:
Before returning the machine to
service, install the undercarriage shroud;
refer to
Installing the Undercarriage Shroud
(page
50).
Spray Filter
Recommendations
Selecting a Suction Filter
Standard Equipment: 50 mesh suction filter (blue)
Use the suction filter table to identify the screen
mesh for the spray nozzles you are using based
on chemicals products or solutions with a viscosity
equivalent to water.
Suction Filter Table
Spray Nozzle
Screen Mesh
Color Code (flow
Size*
rate)
Yellow (0.2 gpm)
50
Red (0.4 gpm)
50
Brown (0.5 gpm)
50 (or 30)
30
Gray (0.6 gpm)
White (0.8 gpm)
30
Blue (1.0 gpm)
30
Green (1.5 gpm)
30
*The mesh size of the suction filters in this table
are based on spray chemicals or solutions with the
viscosity equivalent to water.
Important:
When you spray with higher viscosity
(thicker) chemical products or solutions with
wettable powders, you may need to use an coarser
screen mesh for the optional suction filter; refer
to
Figure
48.
Mesh size—chemical or solution viscosity
1. Higher-viscosity chemicals
or solutions
2. Lower-viscosity chemicals
or solutions
42
Filter Color Code
Blue
Blue
Blue (or green)
Green
Green
Green
Green
Figure 48
3. Screen mesh size
g214212