Toro Multi Pro 5800-D Operator's Manual page 81

Hide thumbs Also See for Multi Pro 5800-D:
Table of Contents

Advertisement

Figure 114
1. Section-bypass valve
2. Quick-connect pins
4.
Loosely assemble the flange clamps that you
removed in
Removing the Section-Manifold
Valve (page 77)
to the flanges of the
section-valve manifold and the flanges of the
other section-valve (s) and/or coupling adapter
(Figure
115).
Figure 115
1. Flange (coupling adapter)
2. Flange (section-manifold
valve)
5.
For left or right section-valve manifolds,
assemble the section-valve manifold to the valve
support
(Figure
113) with the 2 flange-head
bolts (1/4 x 3/4 inch) and 2 flange locknuts
(1/4 inch) that you removed in
Section-Manifold Valve (page
g191303
3. Quick-connect coupler
(section supply hose)
4. Quick-connect fitting
(agitation valve manifold)
g191300
3. Section-manifold valve
4. Flange clamps
Removing the
77).
6.
Torque the flange-head bolts and flange locknuts
to 1978 to 2542 N∙cm (175 to 225 in-lb).
7.
Tighten the 2 flange clamps by hand
115).
8.
Assemble the quick-connect coupler of the
section hose onto the quick-connect fitting of the
section-valve manifold with the quick-connect
pin
(Figure
114).
9.
If you loosened the mounting hardware of the left
or right section-valve manifolds, tighten the nut
and bolt to 1978 to 2542 N∙cm (175 to 225 in-lb).
Installing the Agitation-Manifold
Valve
1.
Align the flange of the agitation-valve manifold
and 3 gaskets with the flanges of the
agitation-bypass valve, pressure filter head, and
coupling adapter
Note:
If needed, loosen the mounting hardware
for the pressure-filter head as needed to provide
clearance.
1. Manifold (agitation valve)
2. Valve support
3. Flange locknut (1/4 inch)
81
(Figure
(Figure 116
and
Figure
Figure 116
4. Flange-head bolt (1/4 x
3/4 inch)
5. Gasket
117).
g191302

Advertisement

Table of Contents
loading

This manual is also suitable for:

41393