Toro Multi Pro 5800-D Operator's Manual page 79

Hide thumbs Also See for Multi Pro 5800-D:
Table of Contents

Advertisement

Figure 110
Agitation Valve Manifold
1. Stem retainer
2. Valve stem
3. Stem port
4. Stem-capture retainer
5. End-cap fitting
6. End-cap seal O-ring
(0.796 x 0.139 inch)
7. Back seating O-ring (0.676
x 0.07 inch)
8. Valve-seat ring
9. Manifold body
10. Ball valve
11. End-cap-fitting assembly
g028243
1. Valve-stem seat
2. Valve-stem assembly
3. Stem port
4. Stem retainer
5. Outlet fitting O-ring (0.737
x 0.103 inch)
6. Coupling (manifold)
3.
Turn the valve stem so that the ball is in the
open position
Note:
When the valve stem is parallel with the
valve flow, the ball slides out.
4.
Remove the stem retainer from the slots in the
stem port in the manifold
111).
5.
Remove the stem retainer and valve stem seat
from the manifold
6.
Reach into the manifold body and remove the
valve-stem assembly
111).
7.
Clean the inside of the manifold and exterior
of the ball valve, valve-stem assembly, stem
capture, and end fittings.
79
Figure 111
Section Valve Manifold
7. End-cap O-ring (0.796 x
0.139 inch)
8. Back seating O-ring (0.676
x 0.07 inch)
9. Ball seat
10. Manifold body
11. Ball valve
12. Coupling assembly
(manifold)
(Figure
109A).
(Figure 110
(Figure 110
and
(Figure 110
g028240
and
Figure
Figure
111).
and
Figure