6.
Installing the Valve Actuator (page 82)
To clean the 3 section valves; refer to the following
sections:
1.
Removing the Valve Actuator (page 76)
2.
Removing the Section-Manifold Valve (page
77)
3.
Cleaning the Manifold Valve (page 78)
4.
Assembling the Manifold Valve (page 80)
5.
Installing the Section-Manifold Valve (page
80)
6.
Installing the Valve Actuator (page 82)
Removing the Valve Actuator
1.
Position the sprayer on a level surface, engage
the parking brake, shut off the spray pump, shut
off the engine, and remove the key.
2.
Remove the retainer that secures the actuator
to the manifold valve for the section valve or
agitation valve
(Figure
Note:
Squeeze the 2 legs of the retainer
together while pushing it down.
Note:
Retain the actuator and retainer for
installation in
Installing the Valve Actuator (page
82).
Figure 103
Section-Valve Actuator Shown (the agitation valve actuator
1. Actuator (section valve)
2. Retainer
3.
Remove the actuator from the manifold valve.
103).
is similar)
3. Stem port
Removing the Agitation-Manifold
Valve
1.
Remove the quick connect pin that secures the
quick-connect coupler for the agitation hose to
the manifold for the agitation valve
1. Flange (pressure-filter
head)
2. Flange (coupling adapter)
3. Flange clamp
2.
Remove the 3 flange clamps that secure the
agitation-valve manifold to the flanges of the
pressure-filter head and the coupling adapter
(Figure
104).
3.
Remove the 2 flange-head bolts (1/4 x 3/4 inch)
and 2 flange locknuts (1/4 inch) that secure the
agitation-valve manifold to the valve support
(Figure
105).
g032545
76
(Figure
Figure 104
4. Quick-connect pin
5. Quick-connect coupler
(agitation hose)
6. Quick-connect fitting
(agitation-valve manifold)
104).
g191301