Engineering Mode - Endurance Console - Landice L-10 Service Manual

Hide thumbs Also See for L-10:
Table of Contents

Advertisement

Engineering Mode – Endurance Console:
FOLLOW THE STEPS BELOW TO ENTER ENGINEERING MODE :
1) Start machine and then pull the safety key out
2) Press Speed Keys + (plus) and – (minus) simultaneously and count 3 seconds.
3) Push the safety key back and then release the + and – keys.
PO1 should appear on the screen. To change between screens, press the ENTER key. To exit Engineering mode
Press STOP key and restart the treadmill.
LISTING OF ENGINEERING OR PARAMETERS SETTINGS:
PO1- Mini Speed (Minimum Speed) should be set to .5mph ENG
PO2- Max Speed (Maximum Speed) should be 15.5 mph for 220v, 12.5mph for 110v models
PO3- Max Incline (Maximum Incline) should be 15
PO4- Speed Accel Time (Speed Acceleration Time) Set to 1.2
PO5- Speed Decel Time 1 (Speed Deceleration Time) Set to 1.2
PO6- Speed Decel Time 2 (Speed Deceleration Time) Set to 2
PO7- Wheel –Set to 4.3
PO8- Total Time- Amount of Time the Treadmill is running
PO9- Total Distance- Distance the belt has traveled
PO10- Error Code Log- Previous Error
PO11- Error Code Log- Previous Error
PO12- Error Code Log – Most recent Error