Om2000A+ Control - OM POWER OM2000A+ Manual

Shortwave plus 50 mhz power amplifier
Hide thumbs Also See for OM2000A+:
Table of Contents

Advertisement

-
OPR/STBY
Short press for switching betwen STBY and OPERATION mode.
-
ON/OFF
Long press (1 sec.) for switching the PA ON (tube heating first), 2 seconds for PA
OFF. Always use the ON/OFF button as this allows for a predetermined (software controlled) time to
cool down the tube and inside the PA compartment.
5.2.

OM2000A+ control

Turn ON the green Main Power switch and the home screen will lights up. Initial control touch buttons
are visible on the bottom line.
Remember that the home touch screen is active for some information and control settings, while the PA
is still OFF!
BAND
Touch the left side of BAND button to go down, touch the right site to go up. The band information is
displayed above the button.
ANTENNA
Transmitting antenna choice. Functional ONLY when the antenna switch is programmed and antennas
are defined (see page 16). This antenna feature allows switching between antennas authorized for the
current band. An external antenna switch is controlled by BCD code at the ANT/BPF output (see
Section 7.9).
13