11. MAINTENANCE, SERVICE AND REPAIR
11.4 Adjust the Air Pressure ( Pneumatic Systems )
11.4.1
Pull up pressure adjustment valve. Set adjustment
valve to the desired value on manometer by turning it
clockwise or counter clockwise. Then lock the valve
by pressing it down.
11.4.2
Set the air pressure between 6 and 8 BAR. If air
pressure drops below the stated values, accessories
operating with pneumatic power do not work.
11.4.3
Conditioner unit accumulates the water in the air in
the collection container so that it won't damage
pneumatic components. At the end of the working
day, empty the accumulated water by opening water
discharge valve under the collection container.
11.4.4
In order to put oil to the oil tank, remove the reservoir
by turning. Oils recommended by the manufacturer
are; TELLUS C10 / BP ENERGOL HLP 10 / MOBIL
DTE LIGHT / PETROL OFİSİ SPINDURA 10