8. PROFILE HEIGHT MEASURING DEVICE
119
8.1.2 If it is Needed to Recalibrate the Machine for any Reason ;
Enter the offset value as 365 mm. Put a calibrating part with a known height under the measuring probe
and measure it with the device. If the height measurement value is bigger than the parts height than add
the difference to 365 mm or if it is smaller than the parts height than subtract the difference from 365 mm
and enter it to offset
8.1.3 Working Page ;
After calibrating the measurement device ( Calibration is done by manufacturer by default ) place the
profile under the measurement device probe. When the " Measure Height " button on the screen is
pressed, the probe will move down and touches the profile, or part, for 1 second. The measured value
will be displayed in the same screen as " Profile Height". ( The " from list " button in the calibration page
must appear red for measuring )