Cleaning In The Event Of An Alarm Or 1 Time / Year - Wexiodisk WD-6 DUPLUS Installation And User Manual

Table of Contents

Advertisement

Operating instructions
Cleaning the filter
When cleaning the filter (15), the tank (13) for the recirculating rinse water must
be empty. The tank is emptied during the daily cleaning programme and when
internal rinsing is started with the P3 programme button.
Removing/fitting the filter
A=Filter housing
B=Filter
C=Cover
Note that the tank for recirculating rinse water should not be full when the filter is
unscrewed, or water will spill out into the dishwashing room.

4.3.5 Cleaning in the event of an alarm or 1 time / year

The machine's condensing battery (option) should be cleaned at least once a
year.
Remove the panel and rinse clean the heat recovery unit.
N.B.! When rinse cleaning the heat recovery unit and the base of the battery box,
do not use more water than the drain under the battery can remove from the
machine. The battery must be cleaned with hot water at normal pressure. Do not
aim the water directly at the fan motor. The electric motor may be damaged if it is
rinsed with high-pressure water.
WD-6 DUPLUS
Unscrew the cover (C) and remove the filter (B). Rinse the filter and cover.
When refitting, it is important to fit the filter correctly to ensure that it is not
damaged and that no leakage occurs.
First fit the filter (B) in the filter housing (A) then ensure that it is sitting
straight.
Fit the cover (C), (does not need to be screwed tight).
48
Rev. 4.0 (202202)

Advertisement

Table of Contents
loading

Table of Contents