PGV*-F213-B16-1.5M-*
Operation and communication
Description Function
AG#
CC1_#/
CC2_#
CC1
ERR
LT/RT
NP
O1_#/
O2_#
S1_#/
S2_#
TAG
TAG#
WRN
XP#
YP#
Z#
TS#
FlashOff
I_Ctrl
Table 5.5
1. Should you have any questions, please contact Pepperl+Fuchs
Error Codes
Error code
2
5
> 1000
48
Absolute angle specification
Control code 1 or 2 with number # detected
Control code 2 is evaluated via the "Split value" function.
Associated control code is detected.
Error message
Error codes are stored in XP00 ... XP23. Additional information on the codes
can be found in the Error Codes table.
Selected direction decision
No absolute X position
Orientation control code for lane. Refer to section "Orientation O" ().
Relative position control code for lane. Refer to section "Side S" ().
Data Matrix tag detected
Data Matrix tag with number # detected
Warning message
Warnings are stored in WRN00 ... WRN13. Additional information on the codes
can be found in the Warning Messages table.
Absolute position in the X direction, signed
Absolute position in the Y direction, signed
Distance of the read head to the code tape/ TAG in Z direction
Timestamp of image acquisition 32 bit unsigned (37.04 ns steps) (Overflow
after 159.07s)
Status bit flash deactivated (1: flash off, 0: flash on)
Status bit flash (1: flash off, 0: flash on)
Description
No clear position can be determined, e.g., difference between
codes is too great, code distance incorrect
No direction decision available
Internal fault
1
Priority
4
2
1