Pepperl+Fuchs PGV -F213-B16-1.5M Series Manual page 16

Incident light positioning system
Table of Contents

Advertisement

PGV*-F213-B16-1.5M-*
Installation
Angle Output
Note
Angles are specified as absolute values. The respective value is calculated from the resolution
selected under "Angle Resolution." With a resolution of 0.1°, an angle of 60° is output as
60°/0.1° = 600.
The read head detects the absolute angle in relation to the tracked lane with a maximum reso-
lution of 0.1°. The angle is specified as an absolute value relative to the tracked lane, as a Data
Matrix code tape contains direction information. The output angle covers the range from 0° to
360°. The resolution can be set to the following values:
0.1°
0.2°
0.5°
Figure 3.4
16
X
α
Y
Absolute angle
X
α
Y