SCPI Command Summary

Subsystem Commands
NOTE
SCPI Command
ABORt
:ACQuire (@chanlist)
:TRANsient (@chanlist)
CALibrate
:CURRent
[:LEVel] <NRf>, (@channel)
:MEASure <NRf>, (@channel)
:PEAK (@channel)
:DATA <NRf>
:DATE <SPD>, (@channel)
:DPRog (@channel)
:LEVel P1 | P2 | P3
:PASSword <NRf>
:SAVE
:STATE <Bool> [,<NRf>]
:VOLTage
[:LEVel] <NRf>, (@channel)
:CMRR (@channel)
:MEASure <NRf>, (@channel)
DISPlay[:WINDow]:VIEW METER1 | METER4
FETCh (Note 1) | MEASure
[:SCALar]
:CURRent [:DC]? (@chanlist)
:VOLTage [:DC]? (@chanlist)
:ARRay
:CURRent [:DC]? (@chanlist)
:VOLTage [:DC]? (@chanlist)
INITiate
[:IMMediate]
:ACQuire (@chanlist)
:TRANsient (@chanlist)
:CONTinuous
:TRANsient <Bool>, (@chanlist)
OUTPut
[:STATe] <Bool> [,NORelay], (@chanlist)
:DELay
:FALL <NRf+>, (@chanlist)
:RISE <NRf+>, (@chanlist)
:INHibit
:MODE LATChing | LIVE | OFF
76
Some [optional] commands have been included for clarity. All settings commands
have a corresponding query. Not all commands apply to all models.
Description
Resets the measurement trigger system to the Idle state
Resets the transient trigger system to the Idle state
Calibrates the output current programming
Calibrates the current measurement
Calibrates the peak current limit (Agilent N6751A/52A/61A/62A)
Enters the calibration value
Sets the calibration date
Calibrates the current downprogrammer
Advances to the next calibration step
Sets the numeric calibration password
Saves the new cal constants in non-volatile memory
Enables/disables calibration mode
Calibrates the output voltage programming
Calibrates common mode rejection ratio (N6751A/52A/61A/62A)
Calibrates the voltage measurement
Selects 1-channel or 4-channel meter view
Returns the average output current
Returns the average output voltage
(Array commands only on Agilent N6761A/62A and Option 054)
Returns the instantaneous output current
Returns the instantaneous output voltage
(Acquire command only on Agilent N6761A/62A and Option 054)
Enables the measurement system to receive triggers
Enables the output transient system to receive triggers
Enables/disables continuous transient triggers
Enables/disables the specified output channel(s)
Sets the output turn-off sequence delay
Sets the output turn-on sequence delay
Sets the remote inhibit input
Series N6700 User's Guide