Appendix E Compatibility
Agilent 662xA Command
IHI <ch>
ILO <ch>
IOUT? <ch>
IRLO <ch>
IRHI <ch>
IRLN <ch>
IRHN <ch>
IRSET <ch>, <x>
IRSET? <ch>
ISET <ch>, <current>
ISET? <ch>
ISTEP <ch>, <x>
METER <ch>
METER?
OCP <ch>, <on/off>
OCP? < ch >
OCRST < ch >
OUT < ch >, < on/off >
OUT? < ch >
194
Description
Generates error −113. Unit must be calibrated using SCPI commands.
Generates error −113. Unit must be calibrated using SCPI commands.
Queries the measured output current of the specified output channel. The
response is a real number. The front panel display can be used to monitor
the measured output current (and voltage) of the selected output channel.
Generates error −113.
Generates error −113.
Generates error −113.
Generates error −113.
Sets the full-scale current range programming for an output channel. The
power system will select the lowest operating range that will contain the
value (x). If the present operating current is greater than the full-scale
range selected, the present output current will be reduced to the full-scale
value of the new range selected. If the current entered is larger than the
highest possible range, an error will result.
Queries the full-scale current range setting of an output channel.
Sets the current of the specified output channel.
Queries the present current setting of the specified output channel. The
response is a real number.
Increases or decreases the output channel current in steps. If the step
value < x > is positive, output current will increase by the step value, if the
step value is negative, the output current will decrease by the step value.
Stepping beyond the active operating range causes an error.
Does nothing.
Always returns a 1.
Enables the over-current protection circuit for the specified output channel.
This circuit, when enabled, causes the output to go to the off state when
the output is in + CC mode. On/off is a 1 to turn on (enable) or a 0 to turn
off (disable) the circuit.
Queries the over-current protection circuit on/off status for the specified
output channel. Response is either a 1 (on) or a 0 (off).
Returns the specified output channel to its previous settings after it has
been turned off by a protection shutdown.
Turns the specified output channel on or off. <on/off> equals 1 to turn the
output on and equals 0 to turn the output off.
Queries whether the specified output channel is turned on or off . The
response is either 1 (on) or O (off).
Similar SCPI
Command
see Appendix B
see Appendix B
MEAS:CURR?
None
None
None
None
SENS:CURR:RANG
SENS:CURR:RANG?
CURR
CURR?
LIST:CURR
None
None
CURR:PROT:STAT
CURR:PROT:STAT?
OUTP:PROT:CLE
OUTP
OUTP?