[SOURce:]LIST:VOLTage:POINts? (@<chanlist>)
[SOURce:]STEP:TOUTput ON|OFF, (@<chanlist>)
[SOURce:]STEP:TOUTput? (@<chanlist>)
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude] <value>|MIN|MAX,(@<chanlist>)
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPLitude]? [MIN|MAX,] (@<chanlist>)
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude] <value>|MIN|MAX, (@<chanlist>)
[SOURce:]VOLTage[:LEVel]:TRIGgered[:AMPLitude]? [MIN|MAX,] (@<chanlist>)
[SOURce:]VOLTage:MODE FIXed|STEP|LIST, (@<chanlist>)
[SOURce:]VOLTage:MODE? (@<chanlist>)
[SOURce:]VOLTage:PROTection:LEVel <value>|MIN|MAX, (@<chanlist>)
[SOURce:]VOLTage:PROTection:LEVel? [MIN|MAX,] (@<chanlist>)
94
This query returns the number of points (steps) in the voltage list,
not the point values. Applies only to models with list capability.
This command specifies whether an output trigger signal is generated
when a transient voltage or current step occurs. The state is either
ON (1) or OFF (0). A trigger is generated when the state is True.
The *RST value = OFF.
These commands set the immediate and the triggered voltage level of
the output channel. The values are programmed in volts. The
immediate level is the output voltage setting. The triggered level is a
stored value that is transferred to the output when a Step transient is
triggered. This command is coupled with [SOURce:]VOLTage:RANGe.
The *RST value = MIN.
These commands determine what happens to the output voltage
when the transient system is initiated and triggered.
FIXed The output voltage remains at the immediate value.
STEP The output goes to the triggered level when a trigger occurs.
LIST The output follows the programmed list step value when a trigger occurs.
This function does not apply to all models (see
The *RST value = FIXed.
This command sets the over-voltage protection (OVP) level of the
output channel. The values are programmed in volts. If the output
voltage exceeds the OVP level, the output is disabled and the
Questionable Condition status register OV bit is set. An over-voltage
condition can be cleared with the Output Protection Clear command
after the condition that caused the OVP trip is removed.
The *RST value = MAX.
Chapter 1, "Model Differences")
Series N6700 User's Guide
.