[SOURce:]LIST:STEP ONCE|AUTO, (@<chanlist>)
[SOURce:]LIST:STEP? (@<chanlist>)
[SOURce:]LIST:TERMinate:LAST ON|OFF, (@<chanlist>)
[SOURce:]LIST:TERMinate:LAST? (@<chanlist>)
[SOURce:]LIST:TOUTput:BOSTep[:DATA] ON|OFF {,ON|OFF}, (@<chanlist>)
[SOURce:]LIST:TOUTput:BOSTep[:DATA]? (@<chanlist>)
[SOURce:]LIST:TOUTput:EOSTep[:DATA] ON|OFF {,ON|OFF}, (@<chanlist>)
[SOURce:]LIST:TOUTput:EOSTep[:DATA]? (@<chanlist>)
[SOURce:]LIST:VOLTage[:LEVel] <volt> {,<volt>}, (@<chanlist>)
[SOURce:]LIST:VOLTage[:LEVel]? (@<chanlist>)
Series N6700 User's Guide
This command specifies how the list responds to triggers. Applies
only to models with list capability.
ONCE Causes the output to remain at the present step until a trigger advances it to
the next step. Triggers that arrive during the dwell time are ignored.
AUTO Causes the output to automatically advance to each step, after the receipt of an
initial starting trigger. The steps are paced by the dwell list. As each dwell time
elapses, the next step is immediately output.
The *RST value = AUTO.
This command determines the output value when the list terminates.
Applies only to models with list capability. The state is either ON (1)
or OFF (0). When ON, the output voltage or current remains at the
value of the last list step. The value of the last voltage or current list
step becomes the IMMediate value when the list completes. When
OFF, and also when the list is aborted, the output returns to the
settings it was at before the list started.
The *RST value = OFF.
This command specifies which list steps generate a trigger out signal
at the beginning of the list step (BOSTep). Applies only to models
with list capability. A comma-delimited list of up to 512 steps may be
programmed. The state is either ON (1) or OFF (0). A trigger is only
generated when the state is set to ON.
The *RST value = 1 step with a value of OFF.
This command specifies which list steps generate a trigger out signal
at the end of the list step's (EOSTep) dwell time. Applies only to
models with list capability. A comma-delimited list of up to 512 steps
may be programmed. The state is either ON (1) or OFF (0). A trigger
is only generated when the state is set to ON.
The *RST value = 1 step with a value of OFF.
This command specifies the voltage setting for each list step in volts.
Applies only to models with list capability. Up to 512 steps may be
programmed. The values are separated by commas.
The *RST value = 1 step with a value of MIN.
Language Dictionary 6