Agilent 662xA Command
OVCAL < ch >
OVRST < ch >
OVSET <ch>, <ovpoint>
OVSET? < ch >
PON < on/off >
PON?
RCL < reg >
RELAY < on/off >
RELAY?
RIRST < ch >
ROM?
SROM?
SRQ < setting >
SRQ?
STO <reg>
STS? <ch>
TEST?
UNMASK <ch>, <setting>
UNMASK? <ch>
VDATA <ch>, <Vlo>, <Vhi>
VHI <ch>
VLO <ch>
Series N6700 User's Guide
Description
Generates error −113. Unit must be calibrated using SCPI commands.
Returns the specified output channel to its previous settings after it has
been turned off by a protection shutdown.
Sets the over-voltage trip point for the specified output channel.
Queries the present over-voltage setting of the specified output channel.
The response is a real number.
Does nothing.
Always returns a 0.
Recalls the settings for all output channels from the specified internal
register. These settings were previously stored using the STO command.
RCL programs all output channels in sequential order to these stored
settings.
Generates error 203. This Option 750 capability is not supported.
Generates error 203. This Option 750 capability is not supported.
Resets all protection functions for the specified channel. This Option 750
capability is supported
Queries the revision of the power system's firmware.
Queries the revision of the power system's firmware.
Does nothing.
Always returns a 0.
Stores the present settings for all output channels in the specified register.
These settings can be recalled when desired.
Queries the present status of the specified output channel. The response
represents the sum of the binary weights of the status register bits.
Always returns a 0.
Sets the bits in the mask register of the specified output channel to the
setting. The setting is an integer that represents the sum of the binary
weights of the bits. The mask register operates in conjunction with the
status and fault registers.
Queries the present setting of the mask register of the specified output
channel. The response is an integer from 0 to 255.
Generates error −113. Unit must be calibrated using SCPI commands.
Generates error −113.
Generates error −113.
Compatibility Appendix E
Similar SCPI
Command
see Appendix B
OUTP:PROT:CLE
VOLT:PROT:LEV
VOLT:PROT:LEV?
*SRE
*SRE?
*RCL
None
None
OUTP:PROT:CLE
*IDN?
*IDN?
*SRQ
*SRQ?
*SAV
STAT:OPER:COND?
STAT:QUES:COND?
*TST?
STAT:OPER:NTR
STAT:OPER:PTR
STAT:QUES:NTR
STAT:QUES:PTR
STAT:OPER:NTR?
STAT:OPER:PTR?
STAT:QUES:NTR?
STAT:QUES:PTR?
see Appendix B
None
None
195

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents