Thank you very much for purchasing Panasonic products. Please read this Instruc-
tion Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which
meet laws or standards, such as OSHA, ANSI or IEC etc., for personnel protec-
tion applicable in each region or country.
Use of control or adjustment or performance of procedures other than those
For details of the setting contents or setting procedure, refer to 'LS series PRO
mode operation guide' in 'Panasonic Industrial Devices SUNX website (http://
1
PART DESCRIPTION
Output 1 operation indicator
Output 2 operation indicator
Laser emission
2
MOUNTING
1. Fit the rear part of the mounting section of the
2. Press down the rear part of the mounting section
the mounting section to the DIN rail.
1.
2.
mounting section is likely to break.
How to mount the sensor head
1. Insert the sensor head connector into the inlet
until it clicks.
2. Fit the cover to the connector.
3
product is not placed to the leftmost position, this product may not operate properly .
Cascading method
1.
on the 35mm width DIN rail.
2.
other, and connect the quick-
connection cables.
3. Mount the optional end plates
(
hold the amplifiers between their
4.
plates.
Dismantling method
1. Loosen the screws of the end
plates.
2. Remove the end plates.
3. Slide the amplifiers and remove
them one by one.
INSTRUCTION MANUAL
WARNING
MODE indicator /
MODE key
Select Modes
Cancel during setting
Jog switch
Turn: Code selecting
2
35mm width DIN rail
1
2
Sensor head
connector
2
1
MOUNTING '.
2
Sub cable
(
Main cable
(
End plate
(
End plate
Slide
I/O CIRCUIT DIAGRAM
NPN output type
Terminal No. of connector type
5V
Internal circuit
PNP output type
Terminal No. of connector type
0V
Internal circuit
*1
Non-voltage contact or NPN transistor open collector
1
5
EXTERNAL INPUT [only for
When 'emission halt', 'limit teaching' or 'full-auto teaching' is set, the time chart is
as follows.
Time chart
input
Emission
Emission
halt
Limit
teaching
Full-auto
teaching
-
6
OPERATION PROCEDURE
Be sure to set each item after selecting the output 1 or the output 2.
The items that can be set in the output 1 and the output 2 respectively are only
1.Threshold value, 2. Output operation, 3. Timer operation and Timer period, and
4.Detection mode. The items other than those are common. (However, in case of
setting with the direct code, a combination of the output 1/2 can be set only for out-
System of basic operation
Slide
two main modes; the ' NAVI ' mode for items and settings that are frequently re-
Cable type / Color code of
quick-connection cable
100mA MAX.
100mA MAX.
Users' circuit
Cable type / Color code of
quick-connection cable
100mA MAX.
Users' circuit
*2
Non-voltage contact or PNP transistor open collector
or
3ms or more
2ms
2ms
Insident light
Teaching ends
intensity setting
Threshold value
Normal operation
calculation 1 sec.
Sampling starts
Sampling ends
Threshold value
calculation 1 sec.
Load
Load
12~24V DC
±10%
12~24V DC
±10%
Load
Load
or
Layout of terminals of
connector type
(P
.
1. + V
2. Output 1
4. Output 2
3.0V
]
High (Low for NPN
Low (High for NPN
Normal operation
Normal operation
-