TEACH : Teaching Mode
Refer to p. 14 ~ for setting procedure
Full-auto Teaching
P. 13
This method is used to set the threshold value while the sensing objects are still
moving on the production line, without stopping the production line.
When using window comparator mode
The 'threshold value' can be set with any of the 3 teaching methods ('1-level
teaching', '2-level teaching' and '3-level teaching').
values', both ON and OFF can occur between the two threshold value levels.
Output
Hysteresis
(L-ON)
1_SL
1-level Teaching
P. 14
This sets the shift value to any desired value, and sets the threshold values (1_SL,
2_SL) by means of 1-level teaching.
Incident light
intensity
9,999
2_SL
P-1
1_SL
0
ON
Output
(L-ON)
OFF
2-level Teaching
P. 15
This carries out 2-level teaching (P-1, P-2) and sets the threshold values (1_SL,
2_SL).
Incident light
intensity
9,999
P-2
2_SL
P-1
1_SL
0
ON
Output
(L-ON)
OFF
3-level Teaching
P. 16 l
This carries out 3-level teaching (P-1, P-2, P-3) and sets the threshold value
(1_SL) between A and B and the threshold value (2_SL) between B and C as
shown in the diagram below.
After teaching, P-1, P-2 and P-3 are automatically assigned in ascending order to
'A', 'B', and 'C'.
Incident light
intensity
9,999
C
2_SL
B
1_SL
A
0
ON
Output
(L-ON)
OFF
7
By setting two 'threshold
ON
OFF
2_SL
Incident light
intensity
9,999
Shift value
Shift value
Time
* In this figure, the incident light intensity of
P-1 is less than that of P-2.
Time
Time