PRO2 Mode

6-1. PRO2 Mode Functions and Settings

PRO2 mode is used mainly for selecting the detailed configuration of the digital display and incident light intensity
data processing.
* Output 1 and output 2 will both be changed to the same settings.
The settings can be carried out in either output 1 mode or output 2 mode.
: Display Switching Function
Refer to p. 32 for setting procedure
Ramco National
(800) 280-6933
www.panasonicsensors.com
In RUN mode, the digital display is fixed to either incident light intensity, % or peak
hold / bottom hold display, but you can select it to be a variable display. (Rising /
trailing differential mode allows only incident light intensity display.)
* The factory setting is for 'no digital display switching'.
* Window comparator mode and hysteresis mode are the only modes that do not
have digital display switching, so that display switching cannot be used in these
modes. (1_SL and 2_SL can be switched.)
No digital display switching
When fixed at the incident light intensity display, the incident light intensity (changed intensity
in rising / trailing differential mode) is displayed within the range of 0 to 9,999. (Note)
Digital display switching
Normal mode
● Incident light intensity display
Incident light intensity
Threshold value
● Peak hold / Bottom hold display
Rising / Trailing differential mode
● Incident light intensity display
Changed intensity
Peak hold value for changed intensity
30
Note: The incident light intensity display can display a maximum value
of 4,000 in H-SP (ultra high-speed) mode and FAST (high-
speed) mode. In STD (standard) mode and U-LG (ultra long-
range) mode, it can display up to a maximum value of 9,999.
● Percentage display
This function displays the incident light
intensity within a range of 0P (0 %) to
999P (999 %), based on the threshold
value as a standard.
Press the
Jog switch.
Press the
Jog switch.
This function displays the peak and bottom
numerical value of the incident light intensity.
Blinking by turns.
Press the
Jog switch.
Threshold value
Press the
Jog switch.
Incident light intensity
Blinking by turns.
Incident light intensity
Press the
Jog switch.
Changed intensity
Press the
Jog switch.