Settings For Navi Mode; Navi Mode Functions And Settings - Panasonic LS-400 Series Operation Manual

Digital laser sensor
Hide thumbs Also See for LS-400 Series:
Table of Contents

Advertisement

4

Settings for NAVI Mode

4-1. NAVI Mode Functions and Settings

In [NAVI mode], frequently changed settings can be easily configured.
Settings for four functions can be configured.
RUN : Normal Sensing Operation
* When you turn the jog switch to '
value will increase or decrease after the threshold value 1 '
Each time the jog switch is pressed, the display switches between the '
threshold value 2.
After '
If you turn the jog switch to '
TEACH : Teaching Mode
Refer to p. 11 ~ for setting procedure
Ramco National
(800) 280-6933
www.panasonicsensors.com
This indicates normal sensing operation. Threshold value (green) and incident light
intensity (red) are displayed in real time. Manual fine adjustment of the 'threshold
value' can be performed during normal sensing operation.
Threshold value
Threshold value fine adjustment function
Turn the jog switch to either '
threshold value.
If there are no key operations after a certain period of time or if the MODE key is
pressed (to change to TEACH), the digital display (green) will blink and the setting
will be confirmed.
Turn
' or '
' or '
' is displayed, the respective threshold value will be displayed.
' when the output 1 '
Turn to '
'
This mode sets the 'threshold value' by utilizing teaching.
When using normal mode
The 'threshold value' can be set with any of the 3 teaching methods, '2-level
teaching', 'limit teaching' and 'full-auto teaching'.
2-level Teaching
2-level teaching is a method of setting the threshold value by teaching the
amplifier two different status conditions - sensing object present and sensing
object absent.
The 'threshold value' is usually set using this method.
Retroreflective type
Limit Teaching
Teaches only the status condition in which no sensing object is within sensing
range (status in which incident light intensity is stable). This method is used to set
a 'threshold value' for conducting sensing in the presence of a background, or
when extremely small objects are to be detected.
Retroreflective type
* The incident light intensity display can
display a maximum value of 4,000 in
H-SP (ultra high-speed) mode and
FAST (high-speed) mode. In STD
(standard) mode and U-LG (ultra long-
Incident light
intensity
range) mode, it can display up to a
maximum value of 9,999.
' (left) or '
Turn
' in window comparator mode or hysteresis mode, the threshold
' or the threshold value 2 '
' is displayed, the following will be displayed.
Automatic
Change
P. 11
Reflective type
P. 12
Reflective type
Very small object
6
' (right) to increase / decrease the
Automatic
Confirmed
' is displayed.
' threshold value 1 and '
Automatic
Confirmed
'

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls-401pLs-401-c2Ls-401