10-2. Output 1 Sensing Mode Settings

Output 1 can be set to one of five sensing modes (normal / window comparator / rising differential / trailing
differential / hysteresis).
Normal
Window
Rising
mode
comparator
differential
mode
mode
Select sensing mode
by turning the Jog switch.
The digital display will quickly
blink to confirm the setting.
To p. 54
Press the
MODE key 5 times.
Turn the Jog switch 6 times
toward the '
' direction.
Press the
Jog switch.
Trailing
Hysteresis
differential
mode
mode
Press the
Jog switch.
Press the
Jog switch.
To p. 54
Press the
MODE key once.
Press the
MODE key once.
1Press the [MODE key] 5 times to select 'PRO mode'.
2Turn the [Jog switch] 6 times toward the '
select 'PRO6 mode'.
3If the [Jog switch] is pressed, the current setting (red) will be
displayed.
* The factory setting is 'normal mode'.
4If the [Jog switch] is turned, the sensing mode (red) will blink
on the digital display.
Select 'sensing mode'.
5If the [Jog switch] is pressed, the setting (red) will quickly
blink on the digital display, confirming the sensing mode.
The digital display (red) will not blink if the setting has not
been changed.
This completes the settings for normal mode, rising
differential mode and trailing differential mode.
For window comparator mode and hysteresis mode,
continue by selecting the teaching method. (P. 54)
6If the [MODE key] is pressed once, the amplifier will return to
'PRO6 mode'.
7Press the [MODE key] once, the amplifier will return to 'RUN
mode' (normal sensing operation).