Full-auto teaching is used to set the threshould value while the sensing objects are still moving on
Full-Auto Teaching
the production line, without stopping the production line.
Place a sensor head within sensing range.
Status condition-moving the production line
Stable sensing
Press the
MODE key once.
Hold down the
Jog switch.
Difference between incident light
intensities is not great enough.
Press the
MODE key 5 times.
1Select 'TEACH mode' by pressing the [MODE key] once.
2Hold down the [Jog switch] for 0.5 sec. or more when in the
status condition when the object moving on the production
line.
3'
' (green) is displayed on the digital display, then the
MODE indicator / TEACH (yellow) will blink. Release the jog
switch when the object has passed.
4Incident light intensity (red) will blink on the digital display,
and the 'threshold value' will be set to a value midway
between the incident light intensities when the sensing
object is present and when it is absent.
5The set 'threshold value' (green) will indicate and the
judgement on the stability of sensing will be displayed.
• When stable sensing can be performed
n The digital display will blink the word '
• When stable sensing cannot be performed
n The digital display will blink the word '
6The incident light intensity (red) will again be displayed,
indicating that configuration is now complete.
7By pressing the [MODE key] 5 times , the amplifer will return
to 'RUN mode' (nomal sensing operation).
13
' (red).
' (red).
Ramco National
(800) 280-6933
www.panasonicsensors.com