Panasonic LS-400 Series Operation Manual page 32

Digital laser sensor
Hide thumbs Also See for LS-400 Series:
Table of Contents

Advertisement

: Display Turning Function
Refer to p. 33 for setting procedure
: ECO Mode Function
Refer to p. 34 for setting procedure
: Period Holding Function
Refer to p. 35 for setting procedure
: Current Value Storage Function
Refer to p. 36 for setting procedure
: Stored Value Comparison Function
Refer to p. 37 for setting procedure
Ramco National
Display Timing for Peak Hold and Bottom Hold
Please note that the peak hold and bottom hold values will be resampled
consecutively.
Incident light intensity
2068
1820
705
146
Peak
hold
Bottom
hold
Display indicates the peak
value or bottom value within
the graph area '
This function can be used to invert the display orientation, according to the
direction of amplifier installation.
* The factory setting is 'Turn OFF'.
When set to Turn OFF
This function turns off the digital display to reduce current consumption.
If no operations are performed for 20 sec., the letters '
digital display will turn off.
If the [MODE key] or the [Jog switch] are operated, the digital display will light up
again.
* The factory setting is 'ECO OFF'.
When set to ECO OFF
This selects whether the peak hold value / bottom hold value during the hold ON
period or the peak hold value / bottom hold value within the digital display refresh
period is displayed.
* The hold function starts operating from the value at the point when operation
returns to RUN mode.
The current incident light intensity value can be stored.
This displays the stored incident light intensity value and the present incident light
intensity value at the same time so that you can check for things such as drops in
incident light intensity.
(800) 280-6933
Time
Display indicates the peak
value or bottom value within
'.
the graph area '
'.
When the period holding function in PRO2 mode is set to hold ON, the peak hold value / bottom hold
value is displayed during the hold ON period.
When set to Turn ON
When set to ECO ON
31
' will blink and then the
Current Consumption
When ECO mode is OFF:
40 mA or less (at 24 V supply voltage)
When ECO mode is ON:
33 mA or less (at 24 V supply voltage)
www.pansonicsensors.com