Pro1 Mode; Pro1 Mode Functions And Settings - Panasonic LS-400 Series Operation Manual

Digital laser sensor
Hide thumbs Also See for LS-400 Series:
Table of Contents

Advertisement

5

PRO1 Mode

5-1. PRO1 Mode Functions and Settings

PRO1 mode is used mainly for configuring the details of basic settings.
* Output 1 and output 2 will both be changed to the same settings.
The settings can be carried out in either output 1 mode or output 2 mode.
: Response Time Change Function
Refer to p. 25 for setting procedure
: Hysteresis Function
Refer to p. 26 for setting procedure
: Shift Function
Refer to p. 27 for setting procedure
: M.G.S. Function
Refer to p. 28 for setting procedure
: Emission Halt Function
Refer to p. 29 for setting procedure
The response times for the LS-400 series can be switched among four levels:
H-SP (ultra high-speed), FAST (high-speed), STD (standard) and U-LG (ultra
long-range). The switching of response times among these four levels will cause
corresponding changes to the sensing range.
* The factory setting is 'STD (standard)'.
Setting
(ultra high-speed)
(high-speed)
150!s (0.15 ms) or less
(standard)
(ultra long-range)
The hysteresis can be switched to one of three settings (small / standard / large)
in all sensing modes except for hysteresis mode.
* The factory setting is 'H-02 (standard)'.
Limit Teaching
Shifts the 'threshold value' by a certain percentage increment during 'limit teaching'.
(The percentage adjustment is variable from approx. 5 % to 200 %, in increments of 1 %).
* The factory setting is '15 % approx'.
When utilizing reflective type sensor head:
If the threshold value is shifted
toward the '
' direction, minute
and severe detections become
possible.
When utilizing retroreflective type sensor head:
If the threshold value is shifted
toward the '
' direction, minute
and severe detections become
possible.
The receiving light sensitivity can be set in three steps (four steps for U-LG mode
only).
This selects whether the laser is emitted or not.
24
Response time
80!s (0.08 ms) or less
500!s (0.5 ms) or less
4 ms or less
*
(small)
: The optimal limit of detection range
(standard)
: Standard
(large)
: Capability of detecting sensing objects having
a vibratory motion
15 % approx. higher when utilizing
reflective type sensor head
(factory setting)
100 %
15 % approx. lower when utilizing
retroreflective type sensor head
(factory setting)
0
The threshold value is variable from approx.
5 % to 200 % (in increments of 1 %).
Ramco National
(800) 280-6933
www.panasonicsensors.com

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ls-401pLs-401-c2Ls-401

Table of Contents