Maintaining the TRU/FLO Compound Meter

Removing the Cover Assembly

Figure 8 Remove Seal Pin
Figure 9 Removing the Registers
Figure 10 Removing the Cover Assembly
14
Complete the following steps to remove the cover assembly.
1
Remove the seal pins from the register. The seal pin can be
removed with a screw driver as indicated in Figure 8.
2
Remove the registers from the TRU/FLO cover assembly.
See Figure 9.
3
Lay the registers aside in an upright position.
4
Remove the cover bolts attaching the cover assembly to the
maincase.
5
The 4-inch and 6-inch TRU/FLOs have two 3/8-16-inch threaded
holes that can be used to help remove the cover assembly from the
maincase. Screw two 3/8-16-inch bolts into the holes to knock the
maincase loose. Then the cover assembly can be pried or lifted from
the body. See Figure 10.
6
Remove the cover assembly from the maincase and set it aside on a
work bench or on another secure surface.
3/8-16-inch
threaded
hole
TRU/FLO Compound Meter Installation and Maintenance Guide
Do not place the cover assembly upside down on top of
the registers when removing the cover.