Performing Maintenance On The T-10 Chamber; Removing The T-10 Chamber - Neptune TRU/FLO Installation And Maintenance Manual

Compound meter
Table of Contents

Advertisement

Maintaining the TRU/FLO Compound Meter
Figure 14 Securing the Cover Assembly
Turbine
Figure 15 Top of Cover Assembly

Performing Maintenance on the T-10 Chamber

Removing the T-10 Chamber

Figure 16 T-10 Plate
16
3
Add the bolts to the maincase and tighten them from 500-inch.lbs to
800-inch.lbs in a cross pattern. See Figure 14.
4
Place the turbine register in the location marked "TURBINE" on
top of the cover assembly. Place the T-10 register in the location
marked "T-10 DISC" on top of the cover assembly. See Figure 15.
Then secure them with the seal pin.
T-10
Complete the following steps to remove the T-10 chamber.
1
Remove the cover assembly. See "Removing the Cover Assembly"
on page 14.
2
Remove the T-10 plate. See Figure 16.
TRU/FLO Compound Meter Installation and Maintenance Guide