Neptune R450 User Manual

Wall and pit arb utility management systems water electric gas
Hide thumbs Also See for R450:

Advertisement

Quick Links

ARB UTILITY MANAGEMENT SYSTEMS
WATER
|
ELECTRIC
|
GAS
R450 Wall and Pit User's Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R450 and is the answer not in the manual?

Questions and answers

Summary of Contents for Neptune R450

  • Page 1 ARB UTILITY MANAGEMENT SYSTEMS WATER ELECTRIC R450 Wall and Pit User's Manual...
  • Page 3 ARB UTILITY MANAGEMENT SYSTEMS WATER | ELECTRIC | GAS R450 Wall and Pit User’s Manual...
  • Page 4 Trademarks used in this manual R450 is a trademark of Neptune Technology Group Inc. Other brands or product names are the trademarks or registered trademarks of their respective holders. FCC Notice This device complies with part 15 of the FCC Rules.
  • Page 5 L'opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l'interférence nocive, et (2) ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée. R450 Wall and Pit MIU User’s Manual Neptune Technology Group Inc. Literature No. UM R450 09.06 1600 Alabama Highway 229 Part No.
  • Page 7: Table Of Contents

    Specifications - R450 Wall MIU ........
  • Page 8 Contents Glossary Index R450 Wall and Pit User’s Manual...
  • Page 9 Wiring a Neptune Encoder Register ........
  • Page 10 Figures Notes: R450 Wall and Pit User’s Manual...
  • Page 11 ............13 R450 Wall and Pit IUser’s Manual...
  • Page 12 Tables Notes: viii R450 Wall and Pit IUser’s Manual...
  • Page 13: Product Description

    This section provides a general description of the R450 Meter Interface Unit (sub- sequently referred to as R450 MIU or MIU). The R450 MIU by Neptune is a compact electronic device that collects meter read- ing data from an encoder register. It then transmits the data for collection.
  • Page 14: Specifications

    2 Specifications This section provides you with the specifications for the R450 MIU. Electrical Specifications Encoder Register Interface Supported Encoder Maximum Cable Length ® 300 feet (91 meters) Neptune ARB ® 500 feet (152 meters) Neptune ProRead (ARB ® and E-Coder (ARB VII) ®...
  • Page 15: Specifications - R450 Pit Miu

    Operating Humidity 0 to 95% Condensing Functional Specifications Register Reading 8 digits MIU ID 9 digits Dimensions and Weight Dimensions Refer to Figure 3 Weight 1.0 lbs. (454 grams) Figure 3 Pit MIU Dimensions R450 Wall and Pit MIU User’s Manual...
  • Page 16: Specifications - R450 Wall Miu

    Operating Humidity 0 to 95% Condensing Functional Specifications Register Reading 8 digits MIU ID 9 digits Dimensions and Weight Dimensions Refer to Figure 4 Weight 1.0 lbs. (454 grams) Figure 4 Wall MIU Dimensions R450 Wall and Pit MIU User’s Manual...
  • Page 17: General Installation Guidelines

    Tables 1 and 2 show the recommended tools and materials you may need to suc- cessfully install the R450 MIU or to replace the MIU’s internal battery. Some items may not apply to your specific installation or the list may not contain all required tools or materials.
  • Page 18: Safety And Preliminary Checks

    MIU ID number on it, verify that it matches the ID numbers on the MIU you are about to install. Verifying/Preparing the Encoder Register This R450 MIU is designed for use with the following encoder registers: • ARB III, IV, and V •...
  • Page 19: Installation Of At Register (Non Pre-Wired Or Potted Only )

    Black / R Green / B Red / G ECRII and ECRIII If required, connect the 3 conductor wire to the encoder register’s terminals per the manufacturer’s instructions. See Figure 5 and Table 3. R450 Wall and Pit MIU User’s Manual...
  • Page 20 Apply sealant liberally and ensure that it encapsulates the terminal screws and exposed wires. (See Figure 7). Neptune requires Novaguard G661 sealant or Dow Corning compound 4. Figure 7 Application of the Sealant Any leak point can cause a reading failure in a submerged meter setting.
  • Page 21 Do not exceed maximum cable lengths as defined in Table 4. If encoder register is pre-wired and potted, use Scotchloks for connecting register to MIU. Proceed to the section specified for either Pit or Wall installation. R450 Wall and Pit MIU User’s Manual...
  • Page 22: Replacing The Miu Battery (Wall And Pit)

    Replacing the MIU Battery (Wall and Pit) Follow these steps to change-out the pit R450 MIU’s internal battery: Removing the Battery 1 Slowly remove the pit lid. Because the MIU is connected to both the antenna in the pit lid and the meter in the pit base, take care not to strain the cable when removing the lid.
  • Page 23: Cutting And Splicing The Battery Wires

    Cutting the battery connection wires one at a time prevents shorting. Ensure the R450 MIU’s black wire is connected to the black wire on the new battery (-) and the red wire is connected to the red wire on the new battery (+).
  • Page 24: Replacing The Transmitter Cover

    Secure the transmitter cover using the two Phillips head screws, until the cover is snug and fully seated. Be careful not to pinch the battery wires between the cover and the housing. Replace the pit lid. R450 Wall and Pit MIU User’s Manual...
  • Page 25: Replacement Parts

    Replacing the MIU Battery (Wall and Pit) Replacement Parts Table 4 lists the available replacement parts for the R450 MIU. Table 4 Available Replacement Parts Part Name Part Number Solid 3 conductor wire, 22 awg (1000 ft.) 6431-352 Dow Corning #4 compound (5.3oz tube)
  • Page 26 Replacing the MIU Battery (Wall and Pit) Notes: R450 Wall and Pit MIU User’s Manual...
  • Page 27 A unique identification number given to each MIU at the factory. The default value is the last programmed plus one. Custom serial numbers are not available. strain relief posts Posts located on the encoder register and the back of the main MIU housing. R450 Wall and Pit User’s Manual...
  • Page 28 The screws on the encoder register face that are used to connect and anchor the three (3) conductor wire to the register. transmission time The time between MIU transmissions. The default is approximately fourteen (14) seconds. Custom time is not available. R450 Wall and Pit User’s Manual...
  • Page 29 5, 7 R450 MIU description, R450 description 3, 4 dimensions 3, 4 dimensions low battery emissions programming replacement parts electrical specifications tools and materials Encoder register 3, 4 weight illustrated R450 Wall and Pit User’s Manual...
  • Page 30 5, 8 exposed 3, 4 weight length splice MIU color code wires splicing 3, 4 storage temperature wires, from battery strain relief wiring posts correct stripper, wire Neptune encoder register register 3, 4 temperature, storage R450 Wall and Pit User’s Manual...
  • Page 32 11570 México, Distrito Federal Fax: (905) 858-0428 Tel: (525) 55203 5294 / (525) 55203 5708 Fax: (525) 55203 6503 neptunetg.com UM R450 09.06 Part No. XXXXX-XXX © Copyright 2006, Neptune Technology Group Inc. Neptune is a registered trademark of Neptune Technology Group Inc.

This manual is also suitable for:

R450 miu

Table of Contents