Neptune TRU/FLO Installation And Maintenance Manual page 30

Compound meter
Table of Contents

Advertisement

Maintaining the TRU/FLO Compound Meter
Figure 20 Square O-ring
Figure 21 Cleaning Around the Chamber
Figure 22 Cleaning Under the Registers
18
7
Check the o-ring integrity. See Figure 20.
8
Clean the magnet and sealing surfaces.
Use medium grit wet/dry sandpaper to clean the areas where
the T-10 chamber was seated in the cover assembly.
See Figure 21.
Lightly rub to remove any collected debris or sediment on the
machined surfaces.
Turn the cover assembly over and clean where the registers
were seated on the cover assembly. See Figure 22.
Lightly clean all areas that touch magnetic components.
Do not rub too hard or you could permanently damage
the machined metal surface.
TRU/FLO Compound Meter Installation and Maintenance Guide