This manual is an unpublished work and contains the trade secrets and confidential information of Neptune Technology Group Inc., which are not to be divulged to third parties and may not be reproduced or transmitted in whole or part, in any form or by any means, electronic or mechanical for any purpose, without the express written permission of Neptune Technology Group Inc.
Page 12
Figures Notes: R450 System New Customer Guide...
Page 13
Vehicle Detail Record Format (Export file only)......C-27 C.14 Company Trailer Record Format (Optional) ......C-27 R450 System New Customer Guide...
Page 14
Tables Notes: R450 System New Customer Guide...
Chapter 1 Introduction The R450™ System New Customer Guide is designed to prepare your utility company for the R450 System. This chapter provides you with an introduction to the implementation process. It explains the focus of the guide, the pre-implementation per- sonnel responsibilities, and general information on system support.
Neptune (ARB III-V) and Sensus (ECR II) absolute encoders. The R450™ meter interface unit (R450 MIU) is compatible with Nep- tune ARBV, ProRead and E-Coder encoders and Sensus ECR II and ICE (ECR III) encoders. When Neptune's E-Coder is connected to the R450,...
- One route at a time - One zone at a time - Randomly. • Determine how data will be entered into the N_SIGHT R450 host software. • Determine the implementation schedule to be used: - When to conduct the site survey...
Know the requirements and specifications of the R450 DC as out- lined in R450 DC Specifications on Page 3-6. • Work with the Utility Manager in selection of the site for the R450 DCs. • Select the professional installers for the project.
R450 MIU Installation and Maintenance Guide, Part Number 12857-001. • Oversee the installation of R450 DCs. Test each R450 MIU installed to be sure it transmits to the • R450 DC. Responsibilities of Neptune Neptune works with the Utility Manager in obtaining the necessary FCC license.
Any return without an RMA will be delayed in processing. Ordering Additional Equipment Please contact your local Neptune sales representative or distributor for prices on additional equipment. This information may also be obtained from the Customer Service Department by calling the toll free number (800) 645-1892.
Chapter 2 R450 System Overview R450 System This section on the R450 System provides you with an overview of the R450 System operations and a breakdown of the system components. System Overview Neptune's R450 System users can get critical, timely data from the field...
At scheduled intervals, each R450 DC communicates the data (R450 MIU IDs, meter readings, E-CoderPLUS data, and Permalog Leak Detection data) to the N_SIGHT R450 host software by GPRS (or other network backhaul such as Ethernet, Wi-Fi, and so forth). During...
Figure 2.1 R450 System Flow Diagram N_SIGHT R450 Host Software N_SIGHT R450 host software can be hosted on-site at the utility on a server specified in Table 3.1 on Page 3-3 or by the Neptune Customer Support Specialists, or the utility can elect to have N_SIGHT R450 host software hosted through Neptune.
450MHz RF transceiver, micro-processor, and AC power supply with the N_SIGHT R450 host software and the host server. The R450 DC operates in temperature extreme ranges of -30° to 85° C. The R450 DC requires 110 VAC because of the robust two-way RF...
R450 System Overview The R450 MIU can be connected to two ProRead or E-Coder absolute encoder registers when the registers are configured in network mode. In addition, the R450 MIU is compatible with the AMR Permalog leak detection sensor from Fluid Conservation Systems, Inc. (FCS) and can provide the utility with a means of detecting water leaks on distribution lines.
Mapping Feature The N_SIGHT R450 Mapping feature is an optional module. This fea- ture allows you to view your R450 System in a variety of ways using standard mapping tools. In order to use this feature, you must enter all the latitude and longitude coor- dinates for each MIU and Data Collector.
Optional headers may be included in the import file for broadcast and route messages. Host Software The N_SIGHT R450 host software resides on a server. The application can be accessed through a Web browser from PCs within the network.
A unique, sequential description of collector for a 48329_0012 given utility (Anytown 12) Customer Special Neptune-assigned unique manufacturing special SXXX Number number used with part numbers. Special refers to the System ID and the frequencies for the cus- tomer. R450 System New Customer Guide...
Page 30
R450 System Overview Notes: 2-10 R450 System New Customer Guide...
This section describes the N_SIGHT R450 host software requirements. N_SIGHT R450 Host Software Requirements The N_SIGHT R450 host software supplies all the control needed in the network and provides the essential functions of network management, meter communications, reporting, database configuration, and alarms monitoring.
Broadband Internet connection (1.5Mbps minimum) System Requirements – Server Specifications Table 3.1 on Page 3-3 describes the minimum recommendation for server installation. R450 System New Customer Guide...
Hard Drive Type: RAID* Recommended Email capability for sending and receiving email messages. *Information Requirements o obtaining the meter reading from an MIU, the R450 DC, In addition t and N_SIGHT R450 host software, the system supports the following information requirements: ...
Page 34
R450 DCs for a minimum of two years With the R450 DCs, can retain the past three rolling days of collected meter data in the case of a power outage or interruption in the communication link with the software ...
Customer Requirements Additional System Requirements and Specifications Meter Requirements The R450 MIU works with Neptune ARB V, ProRead, E-Coder, and Sensus ECR II & ECR III. E-Coder An electronic digital encoder register that has a Proprietary inte- grated circuit that provides absolute registration with no internal battery requirement.
Mechanical Specifications Maximum Weight 71.5 pounds 32.5 Kg R450 DC Footprint R450 Data Collector 8’ X 8’ Triangle Stand (Valmont) 2.4M X 2.4M Triangle Safety Approval UL Listed Per 60950-1 CSA C22.2 No. 60950-1 R450 System New Customer Guide...
PCs throughout the utility. The server hosting the database requires a static Internet Protocol (IP) address in order for the R450 DCs to be able to synchronize with the database. The IP address is coded into each R450 DC in the system.
Customer Requirements Small Mail Transfer Protocol (SMTP) for Emails A key component of the R450 System is the ability to send out emails for a wide range of applications: • Configuration packets for the installers – either emails or Short Message Service (SMS) text messages •...
Wi-Fi and Ether- net. • All proposed R450 DC sites must have access to electrical power and either a GPRS or a TCP/IP communication link to send mes- sages to the N_SIGHT R450 host software.
Page 40
Customer Requirements Notes: 3-10 R450 System New Customer Guide...
• Assist with discussions/negotiations with the owners to gain access for the R450 DC installations, if buildings or other non-city-owned sites or towers are suggested as the best locations for R450 DCs to be installed • Secure cellular service contracts for each R450 DC (if Ethernet is available at tower sites, this is not necessary) •...
• Records of customers with their account and meter information. In order for your R450 System to work in the most efficient way, the information contained on the Customer Profile Sheet is critical to the implementation of R450 System. Allow ample time to complete this step.
The installer swipes an MIU to see if communications are connected, and if the MIU can transmit and receive with the R450 DC. At least one R450 MIU must be installed in order to test the power of the R450 DC.
Implementation Steps for R450 System Step Five: Onsite System Training The R450 System Training is composed of two segments: Software Training and Customer Service Personnel Training. The software train- ing involves the System Operator, usually the office manager or the sec- ond person in charge.
Refer to the following information for visits from the Neptune System Implementation Specialist. • First site visit: Neptune is on site for first R450 DC installation, configuration and synchronization, testing MIU communication to R450 DC, preliminary demonstration and overview of the host software.
Page 46
Implementation Steps for R450 System Notes: R450 System New Customer Guide...
R450 DCs. Once the modeling is complete, a proposal is discussed with the utility outlining implementation and infrastructure requirements. This chapter explains in detail the steps needed to prepare for the propagation analysis and how this helps your initial site visit by Neptune's Implementation Specialist.
Page 48
Finding out other RF systems used by the utility to minimize inter- ference • Seeking information for the antenna location. Antenna location can be important on a tower Refer to Figure B.1 on Page Appendix B-2 for an example of the Propagation Analysis Request Form. R450 System New Customer Guide...
Calculations and analysis are performed FCC Licensing The R450 System components are approved by the FCC as Part 90 com- ponents and must operate under an FCC license (due to the high power transmitter). Neptune secures the FCC license based on a frequency determined to be the best for the coverage area and transfers the license to the utility upon request.
Page 50
Propagation Analysis Notes: R450 System New Customer Guide...
The completed route (combination of fixed and mobile) is then exported back to the CIS for billing. N_SIGHT R450 is used for col- lecting and monitoring daily reads and customer profile data.
Within N_SIGHT R900 in the handheld section, highlight the selected routes from which you want to obtain readings. Selecting Extract Fixed Network reads sends the list of MIU IDs to the N_SIGHT R450 host software. Any IDs that match the N_SIGHT R450 database are popu- lated with the latest reading (within the last three days).
Appendix A Required Form One Required Form Only one form, the R450 System Customer Profile Form, is required prior to implementing an R450 System. A sample form is illustrated in Figure A.1 on Page Appendix A-2. N_SIGHT R450 New Customer Guide...
Page 54
Required Form Figure A.1 Sample Customer Profile Form Appendix A N_SIGHT R450 New Customer Guide...
Take a preliminary look at the utility account area to determine the extent of R450 System coverage. The following figure provides an illustration of a Sample Propagation Analysis Request Form used by Neptune to conduct the propagation study prior to the implementation of R450 System. N_SIGHT R450 New Customer Guide...
Page 56
Propagation Analysis Request Form Figure B.1 Sample Propagation Analysis Page 1 Appendix B N_SIGHT R450 New Customer Guide...
Page 57
Propagation Analysis Request Form Figure B.2 Sample Propagation Analysis Page 2 N_SIGHT R450 New Customer Guide Appendix B-3...
Page 58
Propagation Analysis Request Form Notes: Appendix B N_SIGHT R450 New Customer Guide...
Appendix C N_SIGHT R900 v4 File Format This appendix includes the file formats used in N_SIGHT R900in order to assist with pushing data in N_SIGHT R450 . It provides an easy ref- erence to the v4 File Format. Default Record Format The v4 File Format consists of one layout that is used for both importing and exporting data.
Additional notes concerning the field, valid format, etc. Quotation marks indicate the only acceptable data for the field. Record Type Hierarchy The following tables represent the format for the record type hierarchy used in v4 record layout. Appendix C N_SIGHT R450 New Customer Guide...
Page 61
Premise Notes PRMNT Premise One per premise. Detail ERT Detail ERTDT Reading Required for ERTs. Reading Detail Record cannot have Detail both an ERT Detail Record and Probe Detail Record. continued on next page N_SIGHT R450 New Customer Guide Appendix C-3...
The following illustrates the sample layout for a typical import file: One Company Header with One Route COMHD RTEHD PRMDT MTRDT RDGDT PRMDT MTRDT RDGDT PRMDT MTRDT RDGDT PRMDT MTRDT RDGDT PRMDT MTRDT RDGDT RTETR COMTR Appendix C N_SIGHT R450 New Customer Guide...
N_SIGHT R900. Table C.3 Company Record Format Column Source Offset Length Type Comment Record ID 'COMHD' Company Code Create Date 10-17 YYYYMMDD Description 18-57 File Version Service Orders Y or N CRLF 60-61 N_SIGHT R450 New Customer Guide Appendix C-11...
Page 70
Deactivate Date 32-39 YYYYMMDD; 00000000 if not used. Route Message 40-119 CRLF 120-121 The Route ID in N_SIGHT R900 is a combination of the Company Code, Of- fice, Cycle, and Route fields. Appendix C N_SIGHT R450 New Customer Guide...
Page 71
Account Number 104-123 Account Status 124-127 Account status codes Premise Custom 1 128-153 Custom display fields for premise screen. Premise Custom 2 154-179 Utility Pass Through 180-307 Any utility-defined informa- tion. CRLF 308-309 N_SIGHT R450 New Customer Guide Appendix C-13...
Page 72
Customer Address Unit 142-156 Customer Address Predir 157-158 Customer Address Street 159-183 Customer Address 184-187 SSuffix Customer Address 188-189 Postdir Customer Address City 190-215 Customer Address State 216-217 continued on next page Appendix C N_SIGHT R450 New Customer Guide...
Page 73
Mail Address Predir 356-357 Mail Address Street 358-382 Mail Address Suffix 383-386 Mail Address Postdir 387-388 Mail City 389-414 Mail State 415-416 Mail Zip 417-427 zzzzz-zzzz Mail Phone 428-437 Permit continued on next page N_SIGHT R450 New Customer Guide Appendix C-15...
Page 74
N_SIGHT R900 v4 File Format Table C.6 Alternate Premise Detail Record Format (continued) Column Source Offset Length Type Comment Premise Custom 1 439-464 Premise Custom 2 465-490 Utility Pass Through 491-618 Email Address 619-668 CRLF 669-670 Appendix C N_SIGHT R450 New Customer Guide...
Page 75
Force Special Instruction 1,266 'Y' or 'N' Force Special Instruction 2 1,267 'Y' or 'N' Changed Force Special 1,268 'Y' or 'N' Instruction Changed Force Special 1,269 'Y' or 'N' Instruction 2 CRLF 1,270- 1,271 N_SIGHT R450 New Customer Guide Appendix C-17...
Page 76
Actual meter number found in field. Meter Type 78-81 Changed Meter Type 82-85 Meter Size 86-93 Changed Meter Size 94-101 Meter Manufacturer 102-104 Three-character code for the meter manufacturer. continued on next page Appendix C N_SIGHT R450 New Customer Guide...
Page 77
134-137 Instruction 1 Read Instruction 2 138-141 Changed Read Instruc- 142-145 tion 2 Seal Number 146-155 Changed Seal Number 156-165 Meter Install Date 166-173 YYYYMMDD. Optional; from billing system. continued on next page N_SIGHT R450 New Customer Guide Appendix C-19...
Page 78
Changed Constant / 259-264 Multiplier Xcoord 265-276 Longitude Ycoord 277-288 Latitude Xcoord2 289-300 For future use Ycoord2 301-312 For future use Xcoord3 313-324 For future use Ycoord3 325-336 For future use CRLF 337-338 Appendix C N_SIGHT R450 New Customer Guide...
Page 79
Order Status 45-46 IN - incomplete CO - complete SK - skipped Skip Code 47-50 Only if order_status = 'SK' Comment Code 1 51-54 Comment Code 2 55-58 Notes Back 59-186 CRLF 187-188 N_SIGHT R450 New Customer Guide Appendix C-21...
Page 80
Dials 50-51 Changed Dials 52-53 Decimals 54-55 Changed Decimals 56-57 Read Direction R, L, C, or blank only Hi Limit 59-68 Low Limit 69-78 Prev Read 79-88 Reading 89-98 continued on next page Appendix C N_SIGHT R450 New Customer Guide...
Page 81
Non-fatal error flag for R900 Electric or Gas Voltage 121-123 Operating meter voltage for R900 Electric MIU Type 124-125 Utility meter type AMR Read Type 126-127 AMR reading type continued on next page N_SIGHT R450 New Customer Guide Appendix C-23...
Page 82
Current Gas Backflow Tamper Current Gas Removal Tamper Current Gas Magnetic Tamper Req ERT Inversion Tamper ERT Reverse Tamper 35-Day Gas Backflow Tamper 35-Day Gas Removal Tamper 35-Day Gas Magnetic Tamper continued on next page Appendix C N_SIGHT R450 New Customer Guide...
Page 83
Record ID 'ERTDT' Tone Freq Channel 8-11 Prev Tamper 1 Use '8' to suppress tam- per check. New Tamper 1 Prev Tamper 2 Use '8' to suppress tam- per check. continued on next page N_SIGHT R450 New Customer Guide Appendix C-25...
Page 84
# Premises 24-29 One input field may be blank if total is unavail- able. # Meters 30-35 One input field may be blank if total is unavail- able. CRLF 36-37 continued on next page Appendix C N_SIGHT R450 New Customer Guide...
Page 85
Table C.14 Company Trailer Record Format (Optional) Column Source Offset Length Type Comment Record ID 'COMTR' Company Code # Routes 10-15 One input field may be blank if total is unavail- able CRLF 16-17 N_SIGHT R450 New Customer Guide Appendix C-27...
'INAC' = Inactive • 'AWZ' = Active Warn on Zero Usage • 'IWU' = Inactive Warn on Usage. These codes may be sent from the host billing computer or created in N_SIGHT R900. Appendix C N_SIGHT R450 New Customer Guide...
Page 87
The date format is YYYYMMDD. Consumption An alphanumeric, 6-character field indicating the amount of water, gas, and electricity billed during the last billing cycle or for the overdue amount in a collection type. N_SIGHT R450 New Customer Guide Appendix C-29...
Page 88
An alphanumeric, 4-character field indicating the street name suffix. Customer Address State An alphanumeric, 2-character field indicating the two-letter state abbrevi- ation code for the customer address. Customer Address Street An alphanumeric, 25-character field indicating the street of the customer address. Appendix C N_SIGHT R450 New Customer Guide...
Page 89
Read field on the handheld display. This field may be included in the CR read type code table record. N_SIGHT R450 New Customer Guide Appendix C-31...
Page 90
Gas No Flow A numeric, 1-digit field indicating a period for which there has been no gas flow: 0: < 7 Days 1: 7 - 14 Days 2: > 14 Days 3: Undefined Appendix C N_SIGHT R450 New Customer Guide...
Page 91
An alphanumeric, 26-character field indicating the street name of the mailing address. Mail Address SSuffix An alphanumeric, 4-character field indicating the street name suffix. Mail Address Unit An alphanumeric, 15-character field indicating the unit for the mailing address. N_SIGHT R450 New Customer Guide Appendix C-33...
Page 92
FR=front right. These codes may be sent from the host billing computer, or they can be created in N_SIGHT R900. Meter Manufacturer An alphanumeric, 3-character field used to identify the manufacturer of the meter. Appendix C N_SIGHT R450 New Customer Guide...
Page 93
R900 electric or gas meter. Notes Back An alphanumeric, 128-character field used to send notes back to the bill- ing system. # Meters An alphanumeric, 6-character field indicating the total number of meters. N_SIGHT R450 New Customer Guide Appendix C-35...
Page 94
Previous Error Count A numeric, 1-digit field used for R900 Electric or Gas tamper. Use '8' to suppress tamper check. Appendix C N_SIGHT R450 New Customer Guide...
Page 95
An alphanumeric, 1-character field designating the direction the meter reading is input into the handheld. This field can be on of the following: • R = Right • L = Left • C= Center • blank N_SIGHT R450 New Customer Guide Appendix C-37...
Page 96
Read Types must match up with the values specified for the meter type because the import file will not override the association defined in the meter type/read type table. Reader ID An alphanumeric, 20-character field identifying the reader used. Appendix C N_SIGHT R450 New Customer Guide...
Page 97
Route Message An alphanumeric, 80-character field used for free-form statements that are downloaded to the handheld for a particular route. The message is displayed on the handheld when the meter reader begins the route. N_SIGHT R450 New Customer Guide Appendix C-39...
Page 98
An alphanumeric, 20-character field used only in the CT trouble code table record describing the corresponding trouble code. These descriptions may be sent from the host billing computer or created in N_SIGHT R900. Appendix C N_SIGHT R450 New Customer Guide...
Page 99
(E-Coder registers only). A numeric, 1-character field indicating the con- secutive days of no consumption detected in the last 35 days. Xcoord A numeric, 12-character field indicating longitude (x-coord). Ycoord A numeric, 12-character field indicating latitude (y-coord). N_SIGHT R450 New Customer Guide Appendix C-41...
Page 100
N_SIGHT R900 v4 File Format Notes: Appendix C N_SIGHT R450 New Customer Guide...
Page 101
Summary N_SIGHT R450 requires data from deployments and/or CIS. Currently data is pushed from the Mobile system to N_SIGHT R450. This does not work well for initial deployments as the N_SIGHT R450 data will not be updated until the next time that the meter is up for billing.
Page 102
All column names have to be lower case. * Value in ( ) indicates field length. • client_id - N_SIGHT R450 must have the client_id filled in on the site table. (client_id will be whatever is in N_SIGHT R450 as the N_SIGHT R900 Lookup)(20) * required •...
Page 103
Direct Data Input into N_SIGHT R450 Database • meter_multiplier - consumption multiplier (12) • display_multiplier - display multiplier (12) • city - city (25) • state - state (2) • zip - zip (10) • image_url - a URL picture to attach to this MIU •...
Page 104
There will be 3 methods for loading pictures: • - URL - a URL is supplied. During the load, the N_SIGHT R450 server will pull the picture from this URL and put it into the data- base associated with the specified MIU. Up to 5 picture URLs may be specified with the following tags: image_url, image_url2, image_url3, image_url4, image_url5 ...
Page 105
The fully qualified name must be accessible from the server by the operating system user running the database. Dur- ing the load, the N_SIGHT R450 server will pull the picture from this file and put it into the database associated with the specified MIU.
Page 106
Direct Data Input into N_SIGHT R450 Database Template A template CSV file called SAMPLE.CSV has been provided with all of the available columns. Instructions • Log into the N_SIGHT R450 server. • Place the CSV file somewhere that the database server has access Open up a command window ...
Page 107
GPRS Demilitarized Zone consumption description of graphs data collector manager readings data project manager – continuous leaks file transfer method conventions, typographical handheld reading system CSA, safety Utility Manager CSV file device, mobile instructions options R450 System New Customer Guide...
Page 108
Index diagnostics that system provides work approval diagram, of system flow frequency review dimensions license direct data input, into N_SIGHT R450 database fields import file 1-40 Trouble Code Description 1-41 Trouble Type 1-39 Meter Readings E-Coder file conversion absolute encoder register...
Page 109
Index installation R450 Data Collector handheld reading system R450 MIU described interface, with other software requirements. See R450 System components interpretation, of data handhelds, system format. See default record format IP address hard disk header record help. See technical support...
Page 110
Ethernet analysis GPRS request form host software study information propagation study meter proposed sites, for R450 Data Collector R450 Data Collector ProRead, encoder register R450 System New Customer Guide...
Page 111
Test R450 MIU SMS text messages toll-free support SMTP, for emails tower specifications sites dimensions specifications electrical trailing zeros environmental conditions functional R450 DC server tower R450 System New Customer Guide...
Page 112
1-41 Trouble Type field typographical conventions, in guide zero consumption usage UL, safety zip code, for utility usage readings zone, Demilitarized Zone Utility Manager zones described responsibilities v4 file format, R900 video adapter visits, onsite R450 System New Customer Guide...