Operation
Message in the display
Icon
Text
INTF18
INTF20
OSSD1F3
OSSDF1
10.3.2
Warnings
Message in the display
Icon
Text
BOOTF
INTF6
EXTTEMP
OVERTEMP
HIGH REFL-
BKG
Operating Manual PSEN sc M 3/5 series
1005055-EN-02
Error/cause
An error occurred during the system
test.
An error occurred during the system
test.
Earth fault has occurred on OSSD1.
An error has occurred when testing
the OSSD1.
Error/cause
An error has occurred when starting
the system.
An error occurred during the system
test.
The ambient temperature is outside
the temperature range indicated in
the
Technical details [
The ambient temperature is outside
the temperature range indicated in
the
Technical details [
The reflection of the background is
too strong.
Description/measure
Perform a
scanner [
If the error persists, please contact
Pilz.
Perform a
scanner [
If the error persists, please contact
Pilz.
Check the EDM state and the
of the OSSDs [
If the error persists, please contact
Pilz.
Check the EDM state and the
of the OSSDs [
If the error persists, please contact
Pilz.
Description/measure
Perform a
scanner [
If the error persists, please contact
Pilz.
Perform a
scanner [
If the error persists, please contact
Pilz.
Ensure that the ambient temperature
is in the temperature range specified
91].
in the
Technical details [
Ensure that the ambient temperature
is in the temperature range specified
91].
in the
Technical details [
Reduce the background reflection or
increase the safety distance (see
Distance to intense light sources and
to reflective surfaces [
reset of the safety laser
85].
reset of the safety laser
85].
wiring
48].
wiring
48].
reset of the safety laser
85].
reset of the safety laser
85].
91].
91].
37]).
| 81