Function description
National and international standards recommend reference outlines for vertical applications
to reliably detect changes in the installation position of the safety laser scanners. This may
be changes due to vibration or changes due to manipulation of the safety laser scanner.
Fig.: Using of a reference outline on a passage
Legend
[1]
[2]
[3]
[4]
[5]-[8]
4.15

Restore configuration

If you experience problems with the configuration, a failed firmware update or any other
situation in which the system is no longer functional, it may be necessary to reset the sys-
tem with a different configuration.
With this function, a configuration can be adopted for further systems and therefore simplify
the configuration of further systems.
Typical applications for restoring a configuration:
}
Configuration of further systems with a similar design
}
Interrupting the supply voltage during the firmware update
}
Forgotten password
}
Incorrect configuration of the IP address