Project configuration
Fig.: Allowance with a detection capability of 40 mm
Legend
[1] Low level
[2] Medium level
[3] High level
5.8
Distance from walls
The edges of the safety zone must have a distance of 40 mm to walls or fixed objects on all
sides.
With this value, the function of the safety laser scanner is ensured. Depending on the re-
flective conditions of the walls or objects, higher allowances may be necessary (see
tance to intense light sources and to reflective surfaces [
Operating Manual PSEN sc M 3/5 series
1005055-EN-02
Allowance Z
R
in mm
400
350
300
250
200
150
100
50
1
INFORMATION
Determining of the allowance when the safety laser scanner has to be
installed near particularly intense or flashing light sources and a re-
flective background.
Use the higher value of the relevant allowances.
[3]
[2]
[1]
Safety distance
(K*T)+C+Z
2
3
without Z in m
37]).
T
R
Dis-
| 40