Checks; Regular Check; Check After Plant/Machine Modification; Maintenance - Pilz PSEN sc M 3 Series Operating Manual

Table of Contents

Advertisement

Safety checks, maintenance and repair
11.2

Checks

11.2.1

Regular check

Regular checks can bring to light changes to the plant/machine, safeguards and ambient
conditions.
Pilz recommends that the safety laser scanner be checked every six months.
}
Check the safety laser scanner's front panel.
– Scratched front panel: Change the safety laser scanner.
– Dirty front panel:
}
Check the tightness of the safety laser scanner.
All screws must be tightened to the torque specified in the
}
Check the safety function of the safety laser scanner (see
the safety laser scanner [
11.2.2

Check after plant/machine modification

Check the safety laser scanner each time the plant/machine is modified. Changing the
safety laser scanner or swapping components of the safety laser scanner should also be
regarded as a modification.
You must comply with the requirements of the applicable national regulations.
The Appendix contains a
check.
11.3

Maintenance

Other than cleaning the front panel, the safety laser scanner requires no other form of
maintenance.
Operating Manual PSEN sc M 3/5 series
1005055-EN-02
Clean the front panel [
In a particularly dirty environment, front panel cleanliness should be checked more
frequently.
INFORMATION
This inspection may only be carried out by qualified personnel.
Checklist [
86].
75]).
101]
which should help you perform the safety
Technical details [
91].
Check the safety function of
| 87

Advertisement

Table of Contents
loading

This manual is also suitable for:

Psen sc m 5 series6d0000166d0000176d0000206d000021Psen sc m 3.0 08-12 ... Show all