YASKAWA CIPR-GA50UВ001AJ Series Installation & Primary Operation page 95

Finless-type ac drive, 200 v class, single-phase input: 1/6 to 3 hp, 200 v class, three-phase input: 1/6 to 25 hp, 400 v class, three-phase input: 1/2 to 25 hp
Table of Contents

Advertisement

*3
Changes when the value set in T2-13 changes.
Input Data
Control Method
Selection
PM Motor Code
Selection
PM Motor Type
PM Motor Rated
Power
PM Motor Rated
Voltage
PM Motor Rated
Current
PM Motor Base
Frequency
Number of PM Motor
Poles
PM Motor Base
Speed
Pull-In Current Level
YASKAWA TOEPC7106170YB YASKAWA AC Drive GA500 Installation & Primary Operation
Table 11.5 Input Data for PM Motor Auto-Tuning
Parameter
Unit
A1-02
-
T2-02
-
T2-03
-
T2-04
kW
T2-05
V
T2-06
A
T2-07
Hz
T2-08
-
T2-09
min
T2-15
%
Auto-Tuning Mode
PM Rotational Auto-Tuning
(4)
5
-
x
x
x
x
x
x
-1
-
x
11 Auto-Tuning
(T2-01 Setting)
Frequency
Injection
6
-
x
x
x
x
-
x
x
x
High
(5)
5, 6
-
-
-
-
-
-
-
-
-
95

Advertisement

Table of Contents
loading

Table of Contents