YASKAWA CIPR-GA50UВ001AJ Series Installation & Primary Operation page 91

Finless-type ac drive, 200 v class, single-phase input: 1/6 to 3 hp, 200 v class, three-phase input: 1/6 to 25 hp, 400 v class, three-phase input: 1/2 to 25 hp
Table of Contents

Advertisement

Table 11.2 Input Data for Induction Motor Auto-Tuning
Input Data
Parameter
Motor Rated
Power
Motor Rated
Voltage
Motor Rated
Current
Motor Base
Frequency
Number of
Motor Poles
Motor Base
Speed
Motor No-Load
Current
Motor Rated Slip
Frequency
Motor Iron Loss
Test Mode
*3
Selection
No-Load Voltage
*1
Shows 0 Hz as the default value. If you do not know the Motor Rated Slip Frequency, keep the setting at 0
Hz.
*2
Input this value when A1-02 = 0 [Control Method Selection = V/f].
*3
If T1-12 = 1 [Test Mode Selection = Yes], when you run the motor in Drive Mode for the first time after
Auto-Tuning, the drive will automatically set E2-02 [Motor Rated Slip] and E2-03 [Motor No-Load
Current].
*4
Input this value when T1-10 [Motor Rated Slip Frequency] = 0 Hz.
*5
Set the same value to No-Load Voltage as T1-03 [Motor Rated Voltage] to get the same characteristics
using Yaskawa 1000-Series drives or other legacy models.
YASKAWA TOEPC7106170YB YASKAWA AC Drive GA500 Installation & Primary Operation
Unit
T1-02
kW
T1-03
V
T1-04
A
T1-05
Hz
T1-06
-
-1
T1-07
min
T1-09
A
T1-10
Hz
T1-11
W
T1-12
-
T1-13
V
Auto-Tuning Mode
(T1-01 Setting)
Rotational
Stationary
Auto-Tuning
Auto-Tuning 1
(0)
x
x
x
x
x
x
-
-
x
*2
x
-
x
*5
x
x
11 Auto-Tuning
Stationary
Line-Line
Resistance
(1)
(2)
x
x
x
-
x
x
x
-
x
-
x
-
x
-
*1
-
-
-
*4
-
*5
-
91

Advertisement

Table of Contents
loading

Table of Contents