8 Overview of Keypad Components and Functions
Illuminated: The keypad controls the Run command (LOCAL Mode).
OFF: The control circuit terminal or serial transmission device controls the Run
command (REMOTE Mode).
Note:
• LOCAL: Use the keypad to operate the drive. Use the keypad to enter Run/
Stop commands and the frequency reference command.
• REMOTE: Use the control circuit terminal or serial transmission to operate
the drive. Use the frequency reference source entered in b1-01 and the Run
command source selected in b1-02.
Illuminated: The drive detects a fault.
OFF: There are no drive faults or alarms.
Flashing:
• Alarm
• Operation Errors
• An Auto-Tuning error
Note:
The LED will illuminate to identify a fault if the drive detects a fault and an
alarm at the same time.
Illuminated: The drive is operating or is ready for operation.
OFF:
• The drive detects a fault.
• There is no fault and the drive received a Run command, but the drive cannot
run. For example, in Programming Mode.
Flashing: The drive is in STo [Safe Torque OFF] condition.
Flashing quickly: The voltage of the main circuit power supply is not in the drive
nameplate specifications, and the external 24 V power supply is providing the only
power to the drive.
Function
35