Finless-type ac drive, 200 v class, single-phase input: 1/6 to 3 hp, 200 v class, three-phase input: 1/6 to 25 hp, 400 v class, three-phase input: 1/2 to 25 hp
Table of Contents

Advertisement

4 Drive Specifications
Item
1000 m (3281 ft) Maximum
Note:
Derate the output current by 1% for each 100 m (328 ft) to install the drive in altitudes
between 1000 m to 4000 m (3281 ft to 13123 ft).
It is not necessary to derate the rated voltage in these conditions:
Altitude
• When you install the drive at 2000 m (6562 ft) or lower
• When you install the drive between 2000 m to 4000 m (6562 ft to 13123 ft) and ground the
neutral point on the power supply.
Contact Yaskawa or your nearest sales representative if you will not ground the neutral
point.
• 10 Hz to 20 Hz: 1 G (9.8 m/s
Vibration
• 20 Hz to 55 Hz: 0.6 G (5.9 m/s
Installation
Install the drive vertically for sufficient airflow to cool the drive.
Orientation
*1
Refer to
Derating Depending on Ambient Temperature on page 32
Item
• UL 61800-5-1
• EN 61800-3
Harmonized
• EN 61800-5-1
Standard
• Two Safe Disable inputs and one EDM output according to EN ISO 13849-1 (Cat.3, PL e),
EN 61800-5-2 SIL3
Protection
IP20/UL Open Type
design
Item
Motor
Electronic thermal overload protection
Protection
Momentary
Drive stops when the output current is more than 200% of the HD output current.
Overcurrent
Protection
Drive stops when the output current is more than these overload tolerances:
• HD: 150% of the rated output current for 60 seconds.
• ND: 110% of the rated output current for 60 seconds.
Overload
Protection
Note:
If output frequency < 6 Hz, the drive can trigger the overload protection function when the
output current is in the overload tolerance range.
12
2
, 32.15 ft/s
2
, 19.36 ft/s
Table 4.2 Standard
Table 4.3 Protection Functions