Manipulation with the programmed device

After selection of desired device for your work, you can insert into the open ZIF socket (the
lever is up) and close socket (the lever is down). The correct orientation of the programmed
device in ZIF socket is shown on the picture near ZIF socket on the programmer's cover. The
programmed device is necessary to insert into the socket also to remove from the socket when
LED BUSY light off.
Note: Programmer's protection electronics protect the target device and the programmer itself
against either short or long-term power failures and, partly, also against a PC failure. However,
it is not possible to grant the integrity of the target device due to incorrect, user-selected
programming parameters. Target device may be not destroyed by forced interruption of the
control program (reset or switch-off PC), by removing the physical connection to the
programmer, but the content of actually programmed cell may remains undefined. Don't unplug
the target device from the ZIF socket during work with device (LED BUSY shine).
In-system serial programming by
DATAMAN-48PRO2 / DATAMAN-48PRO2C
For general definition, recommendation and direction about ISP see section Common notes /
ISP please.
Description of ISP connector
As ISP connector is used 20 pins connector 2-1634689-0 from TE connectivity or other
compatible connector.
2
4
6
8
1
3
5
7
Front view at ISP connector of programmer.