used for device reading operation. Enable/Disable socket checkbox array allows user to set
enabling and disabling of each socket individually. Disabled sockets are ignored for any device
operation.
Programmer / Automatic YES!
This command is used for setting Automatic YES! mode. In this mode you just take off the
programmed device, then put new device into ZIF socket and a last operation will be repeated
automatically. Program automatically detects an insertion of a new device and runs last
executed operation without pressing any key or button. An insertion of device into ZIF is
displayed on the screen. Repeated operation executing will be cancelled by pressing key
<ESC> during waiting for insert/remove a device to/from ZIF.
After an operation with a device is executed, one of the OK or ERROR (status) LEDs on the
programmer will lights in dependence on the result of an operation and the BUSY LED will
blinking.
If the program detects removal of a device, then status LED will switched off, but the BUSY
LED will still blinking to indicate readiness of the program to repeat last operation with new
device.
After the program indicates one or more pins of (new) device in the ZIF socket of the
programmer, the BUSY LED will goes to light continually. From this the program will wait a
requested time for insert the rest pins of new device. If a requested time (Device insertion
complete time) overflows and a device is not correctly inserted, the program will light the
ERROR LED to indicate this state. After new device was inserted correctly, the program will
switch off all status LEDs, except BUSY, and will start an operation with new device.
This mode may be enabled or disabled by item Automatic YES! mode. If a new programmer
is selected Options / Find programmer, this mode will be disabled.
The Response time is interval between insertion of the chip into the ZIF socket and the start
of selected device operation. If longer positioning of the chip in the ZIF socket is necessary
select elongated response time.
Programming adapter used shows name of adapter used with currently selected device.
Pins of programmer's ZIF excluded from sensing contains list of pins that will be ignored
from testing by Automatic YES!. The reason to ignore the pins is mostly - capacitors connected
to these pins.
Button Setting Automatic YES! parameters will run wizard that can detect permanently
connected pins (pins with capacitors) and set these pins to list of pins excluded from sensing.
After selecting of device, list of excluded pins contains default excluded pins for selected
device adapter. If other bypass capacitors to universal programmer and/or device adapter are
added by customer, there is necessary to run Automatic YES! parameters wizard to override
default parameters and detect other pins with capacitors.
In Device removal hold off time is time period between you removed device from the ZIF
socket and the time when software starts to check the socket for new device inserted. This
interval is in seconds and must be from 1 to 120 (default value is 2 seconds).
In Device insertion complete time is possible to set a time within all pins of the device have
to be properly inserted after a first pin(s) detected so that the program will not detects