/Saveproject:<file_name>
Please note, the file name Windows conventions must be fulfilled. It means also, that when file
name contains spaces, the command line parameter must have the file name bounded inside
quotation marks.
Examples:
/prj:c:\myfile.eprj
Load project file with name c:\myfile.eprj.
/loadfile:"c:\filename with spaces.bin"
Load file "c:\filename with spaces.bin" to buffer.
/Program[:switch]
switch 'noquest'
switch 'noanyquest'
Examples:
/Program
/Program:noquest
/Program:noanyquest
/Close
/Close: always
/Eprom_Flash_Autoselect[:xx]
Basic rules for using of executive command line parameters:
command line parameters are not case sensitive
command line parameters can be used when first starting of program or when program is
already running
if program is already running, then any of command line operation is processed only when
program was not busy (no operation was currently executing in program). Program must be
in basic state, i.e. main program window focused, no modal dialogs displayed, no menu
commands opened or executed.
order of processing command line parameters when using more parameters together is
defined firmly as following:
the command is used to save currently selected device type,
buffer contents and configuration to project file. Command
/Saveproject:... is equivalent to user selected command
Save project in PG4UW control program.
forces start of "Program device" operation automatically when
program is starting, or even if program is already running, also one
of following optional switches can be used:
forces start of device programming without question
forces start of device programming without question and after
operation on device is completed, program doesn't show "Repeat"
operation dialog and goes directly into main program window
this parameter has sense together with /Program parameter only,
and makes program to close automatically after device programming
is finished successfully
this parameter has sense together with /Program parameter only,
and makes program to close automatically after device programming
is finished, no matter if device operation was successful or not.
forces automatic select EPROM or FLASH by ID when program is
starting or even if program is already running. xx means pins number
of device in ZIF (this time are valid 28 or 32 pins only) and it is
required just for older programmers without insertion test capability.
For others programmers the value is ignored.