Dataman 448PRO2 User Manual page 90

Table of Contents

Advertisement

Supply voltage (in mV) - supply voltage in target system. Control program checks or sets (it
depends on programmer type) entered supply voltage in target system before every action on
device.
Disable test supply voltage - disables measure and checking supply voltage of programmed
device, set in Supply voltage edit box, before action with device.
Delay after reset active - this parameter determine delay after Reset signal active to start
action with device. This delay depends on values of used devices in reset circuit of device and
can be chosen from these values: 10ms, 50ms, 100ms, 500ms or 1s.
Inactive level of ISP signals - this parameter determine level of ISP signals after finishing
access to target device. Signals of ISP connector can be set to Pull-up (signals are tied
through 22k resistors to supply voltage) or Pull-down (signals are tied through 22k resistors to
ground).
Keep ISP signals at defined level after operation - enables keeping set level of ISP signals
after access to target device finished. Control program indicates activated pull-up/pull-down
resistors by displaying window with warning. After user close this window control program will
deactivate resistors.
group Programming parameters
This group is available for some types of devices. It contains settings of which device parts or
areas have to be programmed.
group Erase parameters
This group is available for some types of devices. It contains special settings of erase modes
of selected device.
Device / Device options / Serialization
Serialization is special mode of program. When a serialization mode is activated, a specified
value is automatically inserted on predefined address into buffer before programming each
device. When more devices are programmed one by one, the serial number value is changed
for each device automatically and inserted into buffer before programming device, so each
device has unique serial number.
There are three types of serialization:
Incremental mode
From file mode
Custom generator mode
Dialog Serialization contains also settings for associated serialization position files that are
used with project files with serialization turned on. For more detailed information about using
serialization in project files, look at Serialization and projects.
Basic rules of serialization:
serialization is associated with recently selected device only. If a new device is selected, the
serialization settings will be reset (serialization will be set to disabled)
serialization settings for recent device are saved along with other settings of the device to
project file or to configuration file when application is closed
90