Device / Device options / Associated file
This command is used for setting associated file with current device. This is a file, which can
be automatic loaded to buffer after device is selected from default devices select list or by start
control program.
You can edit the associated file name in file name box, put a full pathname. The control
program checks the present of this file on the disk. Also is possible enabling or disabling
automatic load of this file.
You can save both settings i.e. associated file and enabling of automatic load of this file to disk
by command File / Exit and save.
Device / Device options / Special options
The special terms used here are exactly the terms used by manufacturer of respective chip.
Please read the documentation to the chip you want to program for explanation of all used
terms.
If the name of this menu item is starting by "View/Edit ...", then the Read device command will
read the content of the chip configuration and it can be viewed and edited by this menu
command.
Device / Blank check
This command executes device blank check. The control program reports a result of this action
by messages in INFO window and LOG.
The menu command Device / Device options / Operation options of PG4UW allows to
customize available operation options.
Device / Read
This command allows reading all device or its part into the buffer. The read procedure can also
read the content of the chip configuration (if it exists and is readable). The special device
configuration areas can be viewed or edited in dialogs available by menu View / Edit buffer
and menu Device / Device options / Special options (Alt+S).
The control program reports a finish of Read action by writing a message to INFO window and
LOG.
The menu command Device / Device options / Operation options allows to set another
working area as the standard. Setting an option Verify data after reading in this menu
command means a higher reliability for device reading.
Device / Verify
This command compares content of the whole device, including special areas and settings (if
available), with data stored in the PC (buffer and/or other storage areas) or in the programmer
itself (depends on the model of the programmer).The control program reports a result of verify
operation to Info window and in the Programmer activity log.
The menu command Device / Device options / Operation options of PG4UW allows to
customize available operation options.